Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Mar 26.
Online ahead of print.

Right mini-parasternotomy may be a good minimally invasive alternative to full sternotomy for cardiac valve operations-a propensity-adjusted analysis

Affiliations
  • PMID: 24667339

Right mini-parasternotomy may be a good minimally invasive alternative to full sternotomy for cardiac valve operations-a propensity-adjusted analysis

K M Chiu et al. J Cardiovasc Surg (Torino). .

Abstract

Aim: Limited realworld data existed for miniparasternotomy approach with good sample size in Asian cohorts and most previous studies were eclipsed by case heterogeneity. The goal of this study was to compare safety and quality outcomes of cardiac noncoronary valve operations by miniparasternotomy and full sternotomy approaches on riskadjusted basis.

Methods: From our hospital database, we retrieved the cases of non-coronary valve operations from 1 January 2005 to 31 December 2012, including re-do, emergent, and combined procedures. Estimated EuroScore-II and propensity score for choosing mini-parasternotomy were adjusted for in the regression models on hospital mortality, complications (pneumonia, stroke, sepsis, etc.), and quality parameters (length of stay, ICU time, ventilator time, etc.). Non-complicated cases, defined as survival to discharge, ventilator use not over one week, and intensive care unit stay not over two weeks, were used for quality parameters.

Results: There were 283 miniparasternotomy and 177 full sternotomy cases. EuroScore-II differed significantly (medians 2.1 vs. 4.7, p<0.001). Propensity scores for choosing miniparasternotomy were higher with lower EuroScore-II (OR=0.91 per 1%, p<0.001), aortic regurgitation (OR=2.3, p=0.005), and aortic non-mitral valve disease (OR=3.9, p<0.001). Adjusted for propensity score and EuroScore-II, mini-parasternotomy group had less pneumonia (OR=0.32, p=0.043), less sepsis (OR=0.31, p=0.045), and shorter non-complicated length of stay (coefficient=7.2 (day), p<0.001) than full sternotomy group, whereas Kaplan-Meier survival, non-complicated ICU time, non-complicated ventilator time, and 30-day mortality did not differ significantly.

Conclusion: The propensity-adjusted analysis demonstrated encouraging safety and quality outcomes for mini-parasternotomy valve operation in carefully selected patients.

PubMed Disclaimer

LinkOut - more resources