Corneal topography patterns in the Tehran eye study: warning about the high prevalence of patterns with a skewed radial axis
- PMID: 24669150
- PMCID: PMC3959046
- DOI: 10.4103/0974-9233.124107
Corneal topography patterns in the Tehran eye study: warning about the high prevalence of patterns with a skewed radial axis
Abstract
Purpose: The purpose of this study is to determine the distribution of corneal topography patterns in Tehran.
Materials and methods: In this population-based study, a total of 442 individuals were randomly selected by cluster sampling for complete ophthalmologic examination. A total of 404 (788 eyes) met the inclusion criteria and were enrolled in this study. Orbscan II (Bausch and Lomb Surgical, Salt Lake City, USA) was used to determine the anterior segment indices and axial power maps for each eye.
Results: On the basis of the axial power maps, the symmetric bowtie (SB) (29.0%) and asymmetric bowtie with inferior steepening (16.7%) patterns were the most prevalent and the irregular (3.3%) and superior steepening (1.5%) patterns the least prevalent. Asymmetric bowtie pattern with a skewed radial axis (AB-SRAX) was seen in 7.6% of eyes. These cases had both thinner and steeper corneas compared with round and SB ones (P < 0.014 and P < 0.006). Maximum anterior elevation in 5 mm zone, of AB-SRAX corneas were higher than other patterns (P < 0.01) except for superior steepened and inferior steepened ones.
Conclusions: The distribution of corneal topographic patterns in Iranians seems like other Asian population on the whole. The 7.6% prevalence of AB-SRAX patterns may be a warning on keratoconus prevalence in our population. This is in line with recent regional reports.
Keywords: Corneal Topography Pattern; Cross-sectional Study; Orbscan II; Tehran.
Conflict of interest statement
Figures


References
-
- Bogan SJ, Waring GO, 3rd, Ibrahim O, Drews C, Curtis L. Classification of normal corneal topography based on computer-assisted videokeratography. Arch Ophthalmol. 1990;108:945–9. - PubMed
-
- Kanpolat A, Simşek T, Alp NM. The evaluation of normal corneal topography in emmetropic eyes with computer-assisted videokeratography. CLAO J. 1997;23:168–71. - PubMed
-
- Kim SJ, Kim DM, Lee JH, Chang BL, Yun DH. Normal corneal topographic patterns of Korean adults. J Korean Ophthalmol Soc. 1996;37:15–21.
-
- Read SA, Collins MJ, Iskander DR, Davis BA. Corneal topography with Scheimpflug imaging and videokeratography: Comparative study of normal eyes. J Cataract Refract Surg. 2009;35:1072–81. - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous