Right heart failure post left ventricular assist device implantation

Affiliations
Review

Right heart failure post left ventricular assist device implantation

Mihalis Argiriou et al. J Thorac Dis. 2014 Mar.

Abstract

Right heart failure (RHF) is a frequent complication following left ventricular assist device (LVAD) implantation. The incidence of RHF complicates 20-50% (range, 9-44%) of cases and is a major factor of postoperative morbidity and mortality. Unfortunately, despite the fact that many risk factors contributing to the development of RHF after LVAD implantation have been identified, it seems to be extremely difficult to avoid them. Prevention of RHF consists of the management of the preload and the afterload of the right ventricle with optimum inotropic support. The administration of vasodilators designed to reduce pulmonary vascular resistance is standard practice in most centers. The surgical attempt of implantation of a right ventricular assist device does not always resolve the problem and is not available in all cardiac surgery centers.

Keywords: Right heart failure (RHF); afterload; assist device; preload.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Ventricular assist devices used in right ventricular failure. (A) Thoratec® pVAD; (B) Abiomed AB5000TM VAD; (C) Thoratec Centrimag® Blood pump; (D) Abiomed BVS 5000TM VAD; (E) TandemHeartTM pVAD.

References

    1. Kormos RL, Teuteberg JJ, Pagani FD, et al. Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes. J Thorac Cardiovasc Surg 2010;139:1316-24 - PubMed
    1. Miller LW, Pagani FD, Russell SD, et al. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 2007;357:885-96 - PubMed
    1. Slaughter MS, Rogers JG, Milano CA, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009;361:2241-51 - PubMed
    1. Pagani FD, Miller LW, Russell SD, et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 2009;54:312-21 - PubMed
    1. Potapov E, Meyer D, Swaminathan M, et al. Inhaled nitric oxide after left ventricular assist device implantation: a prospective, randomized, double-blind, multicenter, placebo-controlled trial. J Heart Lung Transplant 2011;30:870-8 - PubMed