Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1989;15(3):146-51.
doi: 10.1007/BF00254628.

Evaluation in vitro and in vivo of two labelling techniques of different 99mTc-dextrans for lymphoscintigraphy

Affiliations
Comparative Study

Evaluation in vitro and in vivo of two labelling techniques of different 99mTc-dextrans for lymphoscintigraphy

K Wingårdh et al. Eur J Nucl Med. 1989.

Abstract

Five dextrans with different molecular weights and charges were labelled with 99mTc. The labelling methods presented by Henze et al. (1982a) and Ercan et al. (1985) were compared. The labelling efficiency was tested with gel column chromatography scanning (GCS), gel chromatography (GC) combined with the Anthrone test, paper chromatography (PC) and thin layer chromatography (TLC). The GCS technique always indicated a lower labelling efficiency than the PC and TLC techniques, which was due to a more optimal separation of the radioactive components. Gel chromatography in combination with the Anthrone test made it easy to identify the different radiochemical components in contrast to the other methods. Dextran solutions were injected subcutaneously bilaterally at the xiphoid processes in rabbits. The injection sites were massaged for 30 s. Uptake in the parasternal lymph nodes was registrated with a scintillation camera. The animals were killed and dissected at the end of the study. This investigation shows that the labelling method of Ercan et al. gives the highest labelling efficiency. Furthermore, the final pH (4.5) for the dextran solution makes it more useful for injection. For quality control of 99mTc-labelled dextran we recommend the Anthrone test as a complement to GC because it is a quick and simple method of determining the dextran content.

PubMed Disclaimer

References

    1. Eur J Nucl Med. 1987;13(9):456-61 - PubMed
    1. Br J Radiol. 1979 Feb;52(614):124-9 - PubMed
    1. J Nucl Med. 1982 Apr;23 (4):348-53 - PubMed
    1. Radiology. 1979 Apr;131(1):205-9 - PubMed
    1. J Nucl Med. 1982 Oct;23 (10 ):923-9 - PubMed

Publication types

LinkOut - more resources