Polyethylene wear and osteolysis is associated with high revision rate of a small sized porous coated THA in patients with hip dysplasia
- PMID: 24698818
- DOI: 10.1016/j.arth.2014.02.027
Polyethylene wear and osteolysis is associated with high revision rate of a small sized porous coated THA in patients with hip dysplasia
Abstract
The outcome of 25 primary THAs in patients with hip dysplasia using the AML Bantam femoral stem (DePuy) is reported. Age at operation averaged 43 ± 10 years. Twenty-two of 25 stems were cementless. All cementless acetabular components had conventional or cross-linked polyethylene and screws. Follow-up averaged 11 ± 5 years (range 4-18). Four cementless stems were revised after 3, 4, 8, and 9 years; 2/3 cemented stems were revised at 8 and 18 years. Femoral revisions demonstrated extensive conventional polyethylene wear, periprosthetic osteolysis and loosening. Five entire cups were revised for wear and loosening; four liners were replaced. Harris Hip Scores for patients with retained stems went from 43 ± 12 to 85 ± 13. High revision rates with the proximally porous coated Bantam stem are due to loss of fixation, often associated with polyethylene wear and osteolysis.
Keywords: cementless; hip dysplasia; hip replacement; outcome.
Copyright © 2014 Elsevier Inc. All rights reserved.
Similar articles
-
Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years.Orthop Traumatol Surg Res. 2009 Dec;95(8):579-87. doi: 10.1016/j.otsr.2009.10.001. Orthop Traumatol Surg Res. 2009. PMID: 19926546
-
Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors.Clin Orthop Relat Res. 2015 Dec;473(12):3762-9. doi: 10.1007/s11999-015-4378-7. Clin Orthop Relat Res. 2015. PMID: 26054482 Free PMC article.
-
Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty. Apropos of 106 cases.Orthop Traumatol Surg Res. 2009 Nov;95(7):478-90. doi: 10.1016/j.otsr.2009.07.007. Epub 2009 Oct 3. Orthop Traumatol Surg Res. 2009. PMID: 19801209
-
High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips.Acta Orthop. 2006 Aug;77(4):575-84. doi: 10.1080/17453670610012638. Acta Orthop. 2006. PMID: 16929433 Review.
-
Catastrophic Periprosthetic Osteolysis in Total Hip Arthroplasty at 20 Years: A Case Report and Literature Review.Orthop Surg. 2022 Aug;14(8):1918-1926. doi: 10.1111/os.13322. Epub 2022 Jul 12. Orthop Surg. 2022. PMID: 35819098 Free PMC article. Review.
Cited by
-
The impact of polyethylene abrasion on the occurrence of periprosthetic proximal femoral fractures in patients with total hip arthroplasty.Eur J Trauma Emerg Surg. 2021 Feb;47(1):211-216. doi: 10.1007/s00068-019-01222-1. Epub 2019 Sep 13. Eur J Trauma Emerg Surg. 2021. PMID: 31520158
-
Results after surgical treatment of periprosthetic proximal femoral fractures. Osteosynthesis with prosthesis preservation vs. prosthesis change.GMS Interdiscip Plast Reconstr Surg DGPW. 2020 Sep 18;9:Doc02. doi: 10.3205/iprs000146. eCollection 2020. GMS Interdiscip Plast Reconstr Surg DGPW. 2020. PMID: 33214984 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical