Accuracy of two wavelength pulse oximetry in neonates and infants
- PMID: 2470014
- DOI: 10.1002/ppul.1950060310
Accuracy of two wavelength pulse oximetry in neonates and infants
Abstract
In 60 neonates (gestational age, 26.5-40 weeks; postnatal age, 1-14 days) and in 11 infants (gestational age, 26-33 weeks; postnatal age, 4.5-38 weeks), the accuracy of two wavelength pulse oximetry was examined. A total of 112 comparisons between transcutaneous pulse oximetry saturation (StcO2, NELLCOR N-100) and arterial oxygen saturation (SaO2, OSM2 RADIOMETER) were obtained. SaO2 ranged from 80 to 100%. Criteria for comparison between StcO2 and SaO2 were standardized: patients in behavioral state 1, StcO2 stable for 2 min, and arterial samples drawn from an indwelling arterial line. StcO2 was significantly related to SaO2 (P less than 0.01), but the difference, StcO2 - SaO2, significantly increased when SaO2 decreased [StcO2 - SaO2(%) = -0.39 SaO2(%) + 37.95; r = -0.64, P less than 0.01]. No significant relationship was found between StcO2 - SaO2 and either bilirubinemia (range, 5-222 mumol/L) or fetal hemoglobin (HbF) (range, 12-95%). We conclude that StcO2 overestimates SaO2 when SaO2 decreases, and this overestimation is not due to high levels of bilirubin or HbF.
Similar articles
-
Accuracy of Pulse Oximetry in the Presence of Fetal Hemoglobin-A Systematic Review.Children (Basel). 2021 Apr 30;8(5):361. doi: 10.3390/children8050361. Children (Basel). 2021. PMID: 33946236 Free PMC article. Review.
-
Pulse oximetry in very low birth weight infants with acute and chronic lung disease.Pediatrics. 1987 Apr;79(4):612-7. Pediatrics. 1987. PMID: 2434913
-
Pulse oximetry for continuous oxygen monitoring in sick newborn infants.J Pediatr. 1986 Dec;109(6):1052-6. doi: 10.1016/s0022-3476(86)80298-0. J Pediatr. 1986. PMID: 2431130
-
Comparative accuracy of pulse oximetry and transcutaneous oxygen in assessing arterial saturation in pediatric intensive care.Crit Care Med. 1990 Jul;18(7):725-7. doi: 10.1097/00003246-199007000-00009. Crit Care Med. 1990. PMID: 2364712
-
Pulse oximetry in neonatal medicine.Clin Perinatol. 1991 Sep;18(3):441-72. Clin Perinatol. 1991. PMID: 1934851 Review.
Cited by
-
Accuracy of Pulse Oximetry in the Presence of Fetal Hemoglobin-A Systematic Review.Children (Basel). 2021 Apr 30;8(5):361. doi: 10.3390/children8050361. Children (Basel). 2021. PMID: 33946236 Free PMC article. Review.
-
Oxygen therapy for infants with chronic lung disease.Arch Dis Child Fetal Neonatal Ed. 2002 Jul;87(1):F11-4. doi: 10.1136/fn.87.1.f11. Arch Dis Child Fetal Neonatal Ed. 2002. PMID: 12091281 Free PMC article. Review.
-
The measurement of accurate fetal hemoglobin and related oxygen saturation by the hemoximeter.Clin Chim Acta. 2006 Dec;374(1-2):75-80. doi: 10.1016/j.cca.2006.05.042. Epub 2006 Jun 6. Clin Chim Acta. 2006. PMID: 16844104 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical