. 2014 Nov;119(11):835-41.
doi: 10.1007/s11547-014-0399-7. Epub 2014 Apr 4.

A single-centre experience of 200 consecutive unselected patients in percutaneous EVAR

Affiliations

A single-centre experience of 200 consecutive unselected patients in percutaneous EVAR

Sergio Petronelli et al. Radiol Med. 2014 Nov.

Abstract

Purpose: This study evaluated the feasibility and safety of percutaneous endovascular aneurysm repair (P-EVAR) in an "unselected" population of patients using Prostar XL closure device, comparing our results with the literature data reported for open EVAR (O-EVAR) and P-EVAR in selected populations.

Materials and methods: We prospectively enrolled 200 patients with abdominal aortic aneurysms to be treated with the P-EVAR procedure, without any selection criteria. Four hundred percutaneous femoral accesses using the Prostar XL closure device were performed. The early follow-up protocol consisted of a Doppler ultrasound (US) examination. Later evaluations were performed with US and computed tomography.

Results: Technical success was achieved in all percutaneous accesses (100 %). Ten early complications related to access site were recorded (10/400; 2.5 %): four pseudoaneurysms and six cases of lower limb ischaemia. Five of ten complications occurred in patients presenting calcification of the common femoral arteries, whereas 4/10 were in patients with "complex" groin anatomy. Eight of ten complications occurred at the access site of the main body of the prosthesis using a sheath size >20 Fr.

Conclusions: Percutaneous endovascular aneurysm repair in "unselected" patients is safe and efficient, with a very low risk of access-related complications, comparable to P-EVAR in selected populations and to the best O-EVAR series.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Vasc Surg. 2003 Jul;38(1):78-82 - PubMed
    1. J Vasc Surg. 2006 Feb;43(2):270-6 - PubMed
    1. J Endovasc Surg. 1997 Nov;4(4):362-9 - PubMed
    1. Dtsch Med Wochenschr. 2002 Jul 5;127(27):1453-7 - PubMed
    1. J Vasc Surg. 2008 May;47(5):919-23 - PubMed

LinkOut - more resources