Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Apr;145(4):434-42.
doi: 10.1016/j.ajodo.2013.12.014.

Comparison of virtual and manual tooth setups with digital and plaster models in extraction cases

Affiliations
Comparative Study

Comparison of virtual and manual tooth setups with digital and plaster models in extraction cases

Joon Im et al. Am J Orthod Dentofacial Orthop. 2014 Apr.

Abstract

Introduction: The aim of this study was to compare the virtual and manual tooth setups with digital and plaster models in extraction cases by measuring various occlusal parameters and applying the American Board of Orthodontics objective grading system.

Methods: Linear intra-arch and interarch dimensions (arch width and length, perimeter, overjet, and overbite), angular variables (tip, torque, and rotation), and American Board of Orthodontics objective grading system scores obtained from a digital virtual setup model were compared with those from a plaster model setup.

Results: The digital virtual setup model resulted in smaller arch perimeters than did the plaster setup model by 2.20 mm in the maxillary arch (P <0.01) and 1.30 mm in the mandibular arch (P <0.05). The digital virtual setup also exhibited significantly lower values for overbite and overjet (P <0.01). The digital virtual setup had tendencies toward mesial angulation of the anterior teeth, labial inclination of the maxillary anterior teeth (P <0.05), and distal in-rotation of the mandibular teeth (P <0.05). The resulting American Board of Orthodontics objective grading system evaluation showed that larger deductions for overjet, occlusal contact, and total score (P <0.01) were required for the digital than for the manual setup model.

Conclusions: Digital and manual setups lead to similar measurements for intra-arch and interarch occlusal variables. However, because of the possibility of collision on proximal and occlusal contact, delicate adjustments in proximal and occlusal contacts are required.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources