Direct qPCR quantification of unprocessed forensic casework samples
- PMID: 24705062
- DOI: 10.1016/j.fsigen.2014.03.003
Direct qPCR quantification of unprocessed forensic casework samples
Abstract
The current short tandem repeat (STR) typing workflow for forensic casework samples involves sample collection, sample screening, DNA extraction, DNA qPCR quantification and STR amplification. Although very effective and powerful, this workflow still has room for improvements. For example, the screening assays in practice do not provide DNA related information and also do not work with touch DNA samples, which make up of the majority of the property crime samples. It is known that not all DNA samples have equal probative values. Considering the DNA backlog situation crime laboratories face today, an effective screening tool would be highly desirable. It would allow forensic scientists to prioritize the DNA samples so that the limited resources would be first spent on samples that would have better chances of producing informative STR profiles. qPCR assay does provide DNA quantity and gender information and would be an ideal screening tool. However, prior to quantification, sample extraction and purification are required. By the time a DNA sample is ready for qPCR quantification, time and resources have already been spent on samples that should have been given low priority or excluded from further processing if DNA quantity and gender information were known. To overcome this problem, a direct quantification technology is developed to allow qPCR quantification of casework samples without the need for DNA extraction and purification. The key to a direct qPCR assay is the PE-Swab, a novel sample collection device. A small sample punch can be generated from a PE-Swab and placed in a qPCR reaction for quantification. After optimizing the punch size and the quantification software baseline setting, accurate DNA quantification can be obtained from a sample without the need to carry out DNA extraction and purification. Proof of concept studies were done with low lever touch samples as well as blood samples. The PE-Swab also allows direct STR amplification of casework samples without the need for DNA extraction. Besides its potential as a screening tool, the direct qPCR assay can also be used to normalize the DNA input for a direct STR amplification reaction. The feasibility of the direct qPCR/direct STR amplification workflow was demonstrated with touch DNA samples and blood stain samples.
Keywords: DNA extraction; Direct STR amplification; Direct qPCR; Direct quantification; Direct real-time PCR; PE-Swab.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Similar articles
-
PE-Swab Direct STR Amplification of Forensic Touch DNA Samples.J Forensic Sci. 2015 May;60(3):693-701. doi: 10.1111/1556-4029.12705. Epub 2015 Feb 15. J Forensic Sci. 2015. PMID: 25684449
-
Direct qPCR quantification using the Quantifiler(®) Trio DNA quantification kit.Forensic Sci Int Genet. 2014 Nov;13:10-9. doi: 10.1016/j.fsigen.2014.06.016. Epub 2014 Jul 5. Forensic Sci Int Genet. 2014. PMID: 25047573
-
Casework direct kit as an alternative extraction method to enhance touch DNA samples analysis.Forensic Sci Int Genet. 2020 Jul;47:102307. doi: 10.1016/j.fsigen.2020.102307. Epub 2020 May 15. Forensic Sci Int Genet. 2020. PMID: 32447230
-
Direct PCR amplification of forensic touch and other challenging DNA samples: A review.Forensic Sci Int Genet. 2018 Jan;32:40-49. doi: 10.1016/j.fsigen.2017.10.005. Epub 2017 Oct 18. Forensic Sci Int Genet. 2018. PMID: 29059581 Review.
-
Advances in forensic DNA quantification: a review.Electrophoresis. 2014 Nov;35(21-22):3044-52. doi: 10.1002/elps.201400187. Epub 2014 Oct 9. Electrophoresis. 2014. PMID: 25088961 Review.
Cited by
-
Assessment of autosomal and male DNA extracted from casework samples using Casework Direct Kit, Custom and Maxwell 16 System DNA IQ Casework Pro Kit for autosomal-STR and Y-STR profiling.Sci Rep. 2019 Oct 10;9(1):14558. doi: 10.1038/s41598-019-51154-4. Sci Rep. 2019. PMID: 31601905 Free PMC article.
-
Can qPCR replace the standard plaque assay in the ASTM F1671 to assess personal protective equipment barrier performance?Int J Cloth Sci Technol. 2024;36(3):385-392. doi: 10.1108/ijcst-06-2024-208. Int J Cloth Sci Technol. 2024. PMID: 39129759 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources