. 2014 Jun;24(6):1204-10.
doi: 10.1007/s00330-014-3153-6. Epub 2014 Apr 5.

MRI-only lesions: application of diffusion-weighted imaging obviates unnecessary MR-guided breast biopsies

Affiliations

MRI-only lesions: application of diffusion-weighted imaging obviates unnecessary MR-guided breast biopsies

Claudio Spick et al. Eur Radiol. 2014 Jun.

Abstract

Objective: To assess if the application of diffusion-weighted imaging (DWI) obviates unnecessary MR-guided biopsies in suspicious breast lesions visible only on contrast-enhanced MRI (CE-MRI).

Methods: This institutional review board (IRB)-approved, retrospective, single-centre study included 101 patients (mean age, 49.5; SD 13.9 years) who underwent additional DWI at 1.5 T prior to MRI-guided biopsy of 104 lesions classified as suspicious for malignancy and visible on CE-MRI only. An experienced radiologist, blinded to histopathologic and follow-up results, measured apparent diffusion coefficient (ADC) values obtained from DWI. Diagnostic accuracy was investigated using receiver operating characteristics (ROC) analysis.

Results: Histopathology revealed 20 malignant and 84 benign lesions. Lesions were masses in 61 (15 malignant, 24.6 %) and non-masses in 43 cases (five malignant, 11.6 %). Mean ADC values were 1.53 ± 0.38 × 10(-3) mm(2)/s in benign lesions and 1.06 ± 0.27 × 10(-3) mm(2)/s in malignant lesions. ROC analysis revealed exclusively benign lesions if ADC values were greater than 1.58 × 10(-3) mm(2)/s. As a consequence, 29 false-positive biopsies (34.5 %) could have been avoided without any false-negative findings. Both in mass and in non-mass lesions, rule-in and rule-out criteria were identified using flexible ADC thresholds based on ROC analysis.

Conclusion: Additional application of DWI in breast lesions visible only on MRI can avoid false-positive, MR-guided biopsies. Thus, DWI should be an integral part of breast MRI protocols.

Key points: DWI measurements are a fast and helpful technique for improved breast lesion diagnosis. DWI application in breast lesions visible only on MRI obviates false-positive, MR-guided biopsies. Flexible ADC thresholds provide rule-in and rule-out criteria for breast lesion malignancy.

PubMed Disclaimer

Similar articles

Cited by

References

    1. AJR Am J Roentgenol. 2009 Sep;193(3):840-9 - PubMed
    1. J Magn Reson Imaging. 2006 Aug;24(2):319-24 - PubMed
    1. J Comput Assist Tomogr. 2002 Nov-Dec;26(6):1042-6 - PubMed
    1. Ann Intern Med. 2008 May 6;148(9):671-9 - PubMed
    1. BMC Cancer. 2010 Dec 29;10:693 - PubMed

Publication types

LinkOut - more resources