Review
. 2014;27(1):3-8.

Capsule endoscopy in patients with cardiac pacemakers, implantable cardioverter defibrillators and left heart assist devices

Affiliations
Review

Capsule endoscopy in patients with cardiac pacemakers, implantable cardioverter defibrillators and left heart assist devices

Dirk Bandorski et al. Ann Gastroenterol. 2014.

Abstract

According to the recommendations of the US Food and Drug Administration and manufacturers, capsule endoscopy should not be used in patients carrying implanted cardiac devices. For this review we considered studies indexed (until 30.06.2013) in Medline [keywords: capsule endoscopy, small bowel endoscopy, cardiac pacemaker, implantable cardioverter defibrillator, interference, left heart assist device], technical information from Given Imaging and one own publication (not listed in Medline). Several in vitro and in vivo studies included patients with implanted cardiac devices who underwent capsule endoscopy. No clinically relevant interference was noticed. Initial reports on interference with a simulating device were not reproduced. Furthermore technical data of PillCam (Given Imaging) demonstrate that the maximum transmission power is below the permitted limits for cardiac devices. Hence, impairment of cardiac pacemaker, defibrillator or left ventricular heart assist device function by capsule endoscopy is not expected. However, wireless telemetry can cause dysfunction of capsule endoscopy recording. Application of capsule endoscopy is feasible and safe in patients with implanted cardiac devices such as pacemakers, cardioverter defibrillators, and left heart assist devices. Development of new technologies warrants future re-evaluation.

Keywords: Capsule endoscopy; cardiac pacemakers; implantable cardioverter defibrillator; interference; left heart assist device.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: Martin Keuchel was a speaker for Given Imaging and Olympus and has received study support from Given Imaging and IntroMedic. Dirk Bandorski, Reinhard Höltgen, Dominik Stunder: None

References

    1. May A, Albert J, Keuchel M, et al. Capsule endoscopy for the diagnosis of small bowel diseases. An updated statement by the endoscopy section of DGVS. Z Gastroenterol. 2010;48:1384–1404. - PubMed
    1. Ladas SD, Triantafyllou K, Spada C, et al. European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases. Endoscopy. 2010;42:220–227. - PubMed
    1. Harris LA, Hansel SL, Rajan E, et al. Capsule endoscopy in patients with implantable electromedical devices is safe. Gastroenterol Res Pract 2013. 2013:959234. - PMC - PubMed
    1. Cuschieri JR, Osman MN, Wong RC, Chak A, Isenberg GA. Small bowel capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators: outcome analysis using telemetry review. World J Gastrointest Endosc. 2012;4:87–93. - PMC - PubMed
    1. Bandorski D, Lotterer E, Hartmann D, et al. Capsule endoscopy in patients with cardiac pacemakers and implantable cardioverterdefibrillators - a retrospective multicenter investigation. J Gastrointestin Liver Dis. 2011;20:33–37. - PubMed