Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device
- PMID: 24720921
- DOI: 10.1016/j.jchf.2013.10.008
Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device
Abstract
Objectives: The aim of this study was to determine whether differences in continuous flow left ventricular assist devices (LVADs) may lead to differences in the von Willebrand profile and the occurrence of bleeding and thromboembolic events.
Background: The HeartMate II (Thoratec Corp., Pleasanton, California) and HeartWare Ventricular Assist Device (HVAD) (HeartWare, Inc., Framingham, Massachusetts) systems are the most frequently implanted LVADs worldwide. In all patients with an axial-flow HeartMate II, acquired von Willebrand syndrome (AvWS) due to the loss of large molecular weight multimers was found. The large molecular weight multimers of the von Willebrand factor (vWF) play a key role in primary hemostasis through interactions with platelets.
Methods: This was a retrospective study of the vWF profile and incidence of bleeding and thromboembolic events in 102 patients receiving the HeartMate II (n = 51) and HVAD (n = 51). Between January 2003 and December 2010, vWF testing was performed in 102 of 175 consecutive patients after LVAD implantation.
Results: AvWS was found in all patients, demonstrated by a decrease in the high molecular weight multimers of vWF to 30 ± 14% in HeartMate II patients and 34 ± 13% in patients with an HVAD. Significant predictors of vWF antigen included age (p = 0.011), number of days on the device (p = 0.035), C-reactive protein (p < 0.001), and blood group (p = 0.007). Bleeding and thromboembolic event rates were similar. However, lower fractions of vWF antigen and high molecular weight multimers did not correlate with the rate of bleeding complications or thromboembolic events.
Conclusions: AvWS developed in all patients after centrifugal or axial flow pump implantation. Different patterns of AvWS were seen between the devices as well as individually. However, the complication rates after implantation were similar.
Keywords: HeartMate II; HeartWare; LVAD; bleeding; von Willebrand syndrome.
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Comment in
-
Are centrifugal ventricular assist devices the answer to reducing post-implantation gastrointestinal bleeding?JACC Heart Fail. 2014 Apr;2(2):146-7. doi: 10.1016/j.jchf.2013.11.008. JACC Heart Fail. 2014. PMID: 24720922 No abstract available.
Similar articles
-
Time course of acquired von Willebrand disease associated with two types of continuous-flow left ventricular assist devices: HeartMate II and CircuLite Synergy Pocket Micro-pump.J Heart Lung Transplant. 2013 May;32(5):539-45. doi: 10.1016/j.healun.2013.02.006. J Heart Lung Transplant. 2013. PMID: 23570742
-
Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device.Circ Heart Fail. 2010 Nov;3(6):675-81. doi: 10.1161/CIRCHEARTFAILURE.109.877597. Epub 2010 Aug 25. Circ Heart Fail. 2010. PMID: 20739614
-
Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices.J Heart Lung Transplant. 2014 Jan;33(1):80-7. doi: 10.1016/j.healun.2013.11.010. Epub 2013 Dec 1. J Heart Lung Transplant. 2014. PMID: 24418734
-
Acquired von Willebrand syndrome associated with left ventricular assist device.Blood. 2016 Jun 23;127(25):3133-41. doi: 10.1182/blood-2015-10-636480. Epub 2016 May 3. Blood. 2016. PMID: 27143258 Free PMC article. Review.
-
Acquired von Willebrand syndrome in a child following Berlin Heart EXCOR Pediatric Ventricular Assist Device implantation: case report and concise literature review.World J Pediatr Congenit Heart Surg. 2014 Oct;5(4):592-8. doi: 10.1177/2150135114539521. World J Pediatr Congenit Heart Surg. 2014. PMID: 25324261 Review.
Cited by
-
Hyperadhesive von Willebrand Factor Promotes Extracellular Vesicle-Induced Angiogenesis: Implication for LVAD-Induced Bleeding.JACC Basic Transl Sci. 2022 Mar 28;7(3):247-261. doi: 10.1016/j.jacbts.2021.12.005. eCollection 2022 Mar. JACC Basic Transl Sci. 2022. PMID: 35411318 Free PMC article.
-
Gastrointestinal bleed after left ventricular assist device implantation: incidence, management, and prevention.Ann Cardiothorac Surg. 2014 Sep;3(5):475-9. doi: 10.3978/j.issn.2225-319X.2014.08.19. Ann Cardiothorac Surg. 2014. PMID: 25452907 Free PMC article.
-
Endocardial Endothelial Dysfunction Progressively Disrupts Initially Anti then Pro-Thrombotic Pathways in Heart Failure Mice.PLoS One. 2015 Nov 13;10(11):e0142940. doi: 10.1371/journal.pone.0142940. eCollection 2015. PLoS One. 2015. PMID: 26565707 Free PMC article.
-
Scaling the Low-Shear Pulsatile TORVAD for Pediatric Heart Failure.ASAIO J. 2017 Mar/Apr;63(2):198-206. doi: 10.1097/MAT.0000000000000460. ASAIO J. 2017. PMID: 27832001 Free PMC article.
-
Early Postoperative Changes in Von Willebrand Factor Activity Are Associated With Future Bleeding and Stroke in HeartMate 3 Patients.ASAIO J. 2025 Jan 1;71(1):27-35. doi: 10.1097/MAT.0000000000002250. Epub 2024 Jun 19. ASAIO J. 2025. PMID: 38896804 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous