Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Sep;112(3):649-57.
doi: 10.1016/j.prosdent.2014.01.012. Epub 2014 Apr 12.

Comparison of the flexural strength and marginal accuracy of traditional and CAD/CAM interim materials before and after thermal cycling

Affiliations
Comparative Study

Comparison of the flexural strength and marginal accuracy of traditional and CAD/CAM interim materials before and after thermal cycling

Jiajing Yao et al. J Prosthet Dent. 2014 Sep.

Abstract

Statement of problem: Limited information is available concerning the properties of computer-aided designed/computer-aided manufactured (CAD/CAM) interim materials.

Purpose: The purpose of this study was to investigate the flexural strength and marginal accuracy of 2 traditional bis-acryl composite resin interim materials (Protemp 4 and Structur 2 SC/QM) and 2 CAD/CAM interim materials (Teilo CAD and VITA CAD-Temp).

Material and methods: Standard specimens (25 × 2 × 2 mm) of the 4 materials were made (n=20). Each group contained 10 specimens fractured under 3-point loading in a universal testing machine with a cross-head speed of 1 mm/min. The other 10 specimens were subjected to 5000 thermal cycles (5°C and 55°C) before testing. Four groups of interim crowns were fabricated from the 4 materials on models of a prepared left maxillary first molar (n=10). Twenty-four hours after cementing the crowns, margin discrepancies were measured under a stereomicroscope. The crowns then were subjected to 5000 thermal cycles (5°C and 55°C), and the margin discrepancies were measured again.

Results: Teilo CAD showed the highest mean flexural strength of the 4 interim materials before and after thermal cycling, and VITA CAD-Temp showed the lowest (P<.05). After thermal cycling, the flexural strength decreased significantly (P<.05). The margin discrepancies were larger for the bis-acryl interim crowns than for the CAD/CAM crowns before and after thermal cycling (P<.05). After thermal cycling, the margin discrepancies in the bis-acryl interim crowns were larger (P<.05); however, no significant differences were found for the margin discrepancies in the CAD/CAM interim crowns (P>.05).

Conclusions: CAD/CAM interim materials were stronger and had better marginal accuracy properties than bis-acryl materials, especially after thermal cycling.

PubMed Disclaimer

Publication types