Characters available in photoplethysmogram for blood pressure estimation: beyond the pulse transit time
- PMID: 24722801
- DOI: 10.1007/s13246-014-0269-6
Characters available in photoplethysmogram for blood pressure estimation: beyond the pulse transit time
Abstract
The continuous and noninvasive blood pressure (BP) measurement based on pulse transit time (PTT) doesn't need cuff and could monitor BP in real time for a long period. However, PTT is just a time index derived from electrocardiogram (ECG) and photoplethysmogram (PPG), while BP-related information within the PPG waveform has seldom been taken into consideration. We hypothesized that PPG waveform feature might be useful for BP estimation. Nine healthy subjects took part in an exercise stress test, including baseline resting, exercise on bicycle ergometry and recovering resting. ECG of lead V5 and PPG from left finger were collected simultaneously, and systolic blood pressure (SBP) and diastolic blood pressure (DBP) were recorded from a cuff sphygmometer on the right wrist. The correlation coefficients were obtained between BP (SBP, DBP and pulse pressure (PP)) and PPG morphological indices (total 15 indices in terms of waveform amplitude, time span and area ratio). Five PPG indices were correlated with both SBP and PP (absolute value of correlation coefficient |r| > 0.6) and were further tested for the capability to BP estimation, which were: (1) PTTA, time delay between the R peak of ECG and the foot point of PPG; (2) RSD, time ratio of systole to diastole; (3) RtArea, area ratio of systole to diastole; (4) TmBB, time span of PPG cycle; (5) TmCA, diastolic duration. Comparisons were made between the measured BP and the estimated BP by regression lines and quadratic curve fitting, respectively. As a result, the mean errors of SBP liner fitting with RSD, RtArea, TmBB and TmCA respectively were 5.5, 5.4, 5.2, 5.1 mmHg, which were smaller than that with PTTA of 5.8 mmHg. And the mean errors of SBP quadratic curve fitting with RSD, RtArea, TmBB and TmCA were all 5.1 mmHg, which were smaller than that with PTTA of 5.7 mmHg. The mean errors of multiple regression for SBP, PP and DBP was 4.7, 4.7, 3.5 mmHg respectively, which were more accurate than the regression with single PTTA of 5.8, 5.3, 5.2 mmHg respectively. However, PPG-based SBP and DBP could under estimate cuff pressure by 8 mmHg and over estimate by 10 mmHg respectively, which is a clinically significant error. In conclusion, the combination of time span (PTT, time ratio of systole to diastole, time span of PPG cycle and diastolic duration) and waveform morphology (area ratio of systole to diastole) could improve the performance of PPG-based BP estimation.
Similar articles
-
Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals.Biomed Eng Online. 2017 Feb 6;16(1):23. doi: 10.1186/s12938-017-0317-z. Biomed Eng Online. 2017. PMID: 28166774 Free PMC article.
-
Using a new PPG indicator to increase the accuracy of PTT-based continuous cuffless blood pressure estimation.Annu Int Conf IEEE Eng Med Biol Soc. 2017 Jul;2017:738-741. doi: 10.1109/EMBC.2017.8036930. Annu Int Conf IEEE Eng Med Biol Soc. 2017. PMID: 29059978
-
New photoplethysmogram indicators for improving cuffless and continuous blood pressure estimation accuracy.Physiol Meas. 2018 Feb 26;39(2):025005. doi: 10.1088/1361-6579/aaa454. Physiol Meas. 2018. PMID: 29319536
-
Cardiovascular risks related to increased diastolic, systolic and pulse pressure. An epidemiologist's point of view.Pathol Biol (Paris). 1999 Jun;47(6):594-603. Pathol Biol (Paris). 1999. PMID: 10472070 Review.
-
Assessing hemodynamics from the photoplethysmogram to gain insights into vascular age: a review from VascAgeNet.Am J Physiol Heart Circ Physiol. 2022 Apr 1;322(4):H493-H522. doi: 10.1152/ajpheart.00392.2021. Epub 2021 Dec 24. Am J Physiol Heart Circ Physiol. 2022. PMID: 34951543 Free PMC article. Review.
Cited by
-
Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study.Biomed Eng Online. 2017 Jan 10;16(1):10. doi: 10.1186/s12938-016-0302-y. Biomed Eng Online. 2017. PMID: 28086939 Free PMC article.
-
Cuffless Blood Pressure Estimation Using Pressure Pulse Wave Signals.Sensors (Basel). 2018 Dec 2;18(12):4227. doi: 10.3390/s18124227. Sensors (Basel). 2018. PMID: 30513838 Free PMC article.
-
How Effective Is Pulse Arrival Time for Evaluating Blood Pressure? Challenges and Recommendations from a Study Using the MIMIC Database.J Clin Med. 2019 Mar 11;8(3):337. doi: 10.3390/jcm8030337. J Clin Med. 2019. PMID: 30862031 Free PMC article.
-
Decision Tree Predictive Learner-Based Approach for False Alarm Detection in ICU.J Med Syst. 2019 May 21;43(7):191. doi: 10.1007/s10916-019-1337-y. J Med Syst. 2019. PMID: 31115734
-
Deep Learning-Based Non-Contact IPPG Signal Blood Pressure Measurement Research.Sensors (Basel). 2023 Jun 13;23(12):5528. doi: 10.3390/s23125528. Sensors (Basel). 2023. PMID: 37420695 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous