Graphene oxide-silica composite coating hollow fiber solid phase microextraction online coupled with inductively coupled plasma mass spectrometry for the determination of trace heavy metals in environmental water samples
- PMID: 24725857
- DOI: 10.1016/j.talanta.2014.01.061
Graphene oxide-silica composite coating hollow fiber solid phase microextraction online coupled with inductively coupled plasma mass spectrometry for the determination of trace heavy metals in environmental water samples
Abstract
In this work, a novel graphene oxide-silica (GO-silica) composite coating was prepared for hollow fiber solid phase microextraction (HF-SPME) of trace Mn, Co, Ni, Cu, Cd and Pb followed by on-line inductively coupled plasma mass spectrometry (ICP-MS) detection. The structure of the prepared graphene oxide and GO-silica composite was studied and elucidated by atomic force microscopy (AFM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR) and X-ray photoelectron spectroscopy (XPS). The GO-silica composite coated hollow fiber was characterized by scanning electron microscope (SEM), and the results show that the GO-silica composite coating possessed a homogeneous and wrinkled structure. Various experimental parameters affecting the extraction of the target metal ions by GO-silica composite coated HF-SPME have been investigated carefully. Under the optimum conditions, the limits of detection (LODs, 3σ) for Mn, Co, Ni, Cu, Cd and Pb were 7.5, 0.39, 20, 23, 6.7 and 28 ng L(-1) and the relative standard deviations (RSDs, c(Mn, Co, Cd)=0.05 μg L(-1), c(Ni, Cu, Pb)=0.2 μg L(-1), n=7) were 7.2, 7.0, 5.6, 7.3, 7.8 and 4.6%, respectively. The accuracy of the proposed method was validated by the analysis of Certified Reference Material of GSBZ 50009-88 environmental water and the determined values were in a good agreement with the certified values. The proposed method has been successfully applied for the determination of trace metals in real environmental water samples with recoveries ranging from 85 to 119%.
Keywords: Environmental water samples; Graphene oxide–silica (GO–silica) composite; Hollow fiber solid phase microextraction; Inductively coupled plasma mass spectrometry; Trace metals.
Copyright © 2014 Elsevier B.V. All rights reserved.
Similar articles
-
Membrane solid phase microextraction with alumina hollow fiber on line coupled with ICP-OES for the determination of trace copper, manganese and nickel in environmental water samples.J Hazard Mater. 2011 Mar 15;187(1-3):379-85. doi: 10.1016/j.jhazmat.2011.01.038. Epub 2011 Jan 15. J Hazard Mater. 2011. PMID: 21288641
-
Thermo-responsive polymer coated fiber-in-tube capillary microextraction and its application to on-line determination of Co, Ni and Cd by inductively coupled plasma mass spectrometry (ICP-MS).Talanta. 2011 Aug 15;85(2):1166-73. doi: 10.1016/j.talanta.2011.05.039. Epub 2011 May 27. Talanta. 2011. PMID: 21726754
-
Dithizone modified magnetic nanoparticles for fast and selective solid phase extraction of trace elements in environmental and biological samples prior to their determination by ICP-OES.Talanta. 2012 Jan 15;88:507-15. doi: 10.1016/j.talanta.2011.11.025. Epub 2011 Nov 12. Talanta. 2012. PMID: 22265534
-
Magnetic materials as sorbents for metal/metalloid preconcentration and/or separation. A review.Anal Chim Acta. 2013 Jul 30;789:1-16. doi: 10.1016/j.aca.2013.04.021. Epub 2013 Apr 29. Anal Chim Acta. 2013. PMID: 23856225 Review.
-
Graphene-based sensors for detection of heavy metals in water: a review.Anal Bioanal Chem. 2014 Jun;406(16):3957-75. doi: 10.1007/s00216-014-7804-x. Epub 2014 Apr 17. Anal Bioanal Chem. 2014. PMID: 24740529 Review.
Cited by
-
Efficacy of engineered GO Amberlite XAD-16 picolylamine sorbent for the trace determination of Pb (II) and Cu (II) in fishes by solid phase extraction column coupled with inductively coupled plasma optical emission spectrometry.Sci Rep. 2018 Dec 3;8(1):17560. doi: 10.1038/s41598-018-35656-1. Sci Rep. 2018. PMID: 30510289 Free PMC article.
-
Carbon-based sorbents and their nanocomposites for the enrichment of heavy metal ions: a review.Mikrochim Acta. 2019 Jul 26;186(8):578. doi: 10.1007/s00604-019-3668-2. Mikrochim Acta. 2019. PMID: 31350596 Review.
-
Graphene oxide as a stationary phase for speciation of inorganic and organic species of mercury, arsenic and selenium using HPLC with ICP-MS detection.Mikrochim Acta. 2018 Aug 22;185(9):425. doi: 10.1007/s00604-018-2960-x. Mikrochim Acta. 2018. PMID: 30136039
-
Dispersive Micro-Solid Phase Extraction Using a Graphene Oxide Nanosheet with Neocuproine and Batocuproine for the Preconcentration of Traces of Metal Ions in Food Samples.Molecules. 2023 May 17;28(10):4140. doi: 10.3390/molecules28104140. Molecules. 2023. PMID: 37241881 Free PMC article.
-
Electrochemical determination of lead(II) and copper(II) by using phytic acid and polypyrrole functionalized metal-organic frameworks.Mikrochim Acta. 2019 Dec 18;187(1):69. doi: 10.1007/s00604-019-4044-y. Mikrochim Acta. 2019. PMID: 31853726
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous