Respiratory variations in the arterial pressure during mechanical ventilation reflect volume status and fluid responsiveness
- PMID: 24737260
- DOI: 10.1007/s00134-014-3285-9
Respiratory variations in the arterial pressure during mechanical ventilation reflect volume status and fluid responsiveness
Abstract
Optimal fluid management is one of the main challenges in the care of the critically ill. However, the physiological parameters that are commonly monitored and used to guide fluid management are often inadequate and even misleading. From 1987 to 1989 we published four experimental studies which described a method for predicting the response of the cardiac output to fluid administration during mechanical ventilation. The method is based on the analysis of the variations in the arterial pressure in response to a mechanical breath, which serves as a repetitive hemodynamic challenge. Our studies showed that the systolic pressure variation and its components are able to reflect even small changes in the circulating blood volume. Moreover, these dynamic parameters provide information about the slope of the left ventricular function curve, and therefore predict the response to fluid administration better than static preload parameters. Many new dynamic parameters have been introduced since then, including the pulse pressure (PPV) and stroke volume (SVV) variations, and various echocardiographic and other parameters. Though seemingly different, all these parameters are based on measuring the response to a predefined preload-modifying maneuver. The clinical usefulness of these 'dynamic' parameters is limited by many confounding factors, the recognition of which is absolutely necessary for their proper use. With more than 20 years of hindsight we believe that our early studies helped pave the way for the recognition that fluid administration should ideally be preceded by the assessment of "fluid responsiveness". The introduction of dynamic parameters into clinical practice can therefore be viewed as a significant step towards a more rational approach to fluid management.
Similar articles
-
Influence of tidal volume on pulse pressure variation and stroke volume variation during experimental intra-abdominal hypertension.BMC Anesthesiol. 2015 Sep 22;15:127. doi: 10.1186/s12871-015-0105-x. BMC Anesthesiol. 2015. PMID: 26395001 Free PMC article.
-
Bench-to-bedside review: functional hemodynamics during surgery - should it be used for all high-risk cases?Crit Care. 2013 Jan 28;17(1):203. doi: 10.1186/cc11448. Crit Care. 2013. PMID: 23356477 Free PMC article. Review.
-
[Experts consensus on the management of the right heart function in critically ill patients].Zhonghua Nei Ke Za Zhi. 2017 Dec 1;56(12):962-973. doi: 10.3760/cma.j.issn.0578-1426.2017.12.017. Zhonghua Nei Ke Za Zhi. 2017. PMID: 29202543 Chinese.
-
[Stroke volume and pulse pressure variation are good predictors of fluid responsiveness in sepsis patients].Acta Med Croatica. 2013 Dec;67(5):407-14. Acta Med Croatica. 2013. PMID: 24979881 Croatian.
-
The value of dynamic preload variables during spontaneous ventilation.Curr Opin Crit Care. 2017 Aug;23(4):310-317. doi: 10.1097/MCC.0000000000000430. Curr Opin Crit Care. 2017. PMID: 28614095 Review.
Cited by
-
The effect of restrictive vs. liberal fluid protocols on ocular parameters in patients undergoing prone spine surgery: a randomized controlled trial.Perioper Med (Lond). 2023 Jun 12;12(1):23. doi: 10.1186/s13741-023-00310-6. Perioper Med (Lond). 2023. PMID: 37308905 Free PMC article.
-
Cardiac power parameters during hypovolemia, induced by the lower body negative pressure technique, in healthy volunteers.BMC Anesthesiol. 2016 Jun 30;16(1):31. doi: 10.1186/s12871-016-0195-0. BMC Anesthesiol. 2016. PMID: 27364749 Free PMC article. Clinical Trial.
-
Respiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia.J Clin Monit Comput. 2018 Apr;32(2):221-226. doi: 10.1007/s10877-017-0013-3. Epub 2017 Mar 16. J Clin Monit Comput. 2018. PMID: 28299589
-
Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine.Intensive Care Med. 2014 Dec;40(12):1795-815. doi: 10.1007/s00134-014-3525-z. Epub 2014 Nov 13. Intensive Care Med. 2014. PMID: 25392034 Free PMC article.
-
Common carotid artery diameter responds to intravenous volume expansion: an ultrasound observation.Springerplus. 2016 Jun 23;5(1):853. doi: 10.1186/s40064-016-2595-5. eCollection 2016. Springerplus. 2016. PMID: 27386302 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources