Current mass spectrometry strategies for the analysis of pesticides and their metabolites in food and water matrices
- PMID: 24737632
- DOI: 10.1002/mas.20307
Current mass spectrometry strategies for the analysis of pesticides and their metabolites in food and water matrices
Abstract
Analysis of pesticides and their metabolites in food and water matrices continues to be an active research area closely related to food safety and environmental issues. This review discusses the most widely applied mass spectrometric (MS) approaches to pesticide residues analysis over the last few years. The main techniques for sample preparation remain solvent extraction and solid-phase extraction. The QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) approach is being increasingly used for the development of multi-class pesticide residues methods in various sample matrices. MS detectors-triple quadrupole (QqQ), ion-trap (IT), quadrupole linear ion trap (QqLIT), time-of-flight (TOF), and quadrupole time-of-flight (QqTOF)-have been established as powerful analytical tools sharing a primary role in the detection/quantification and/or identification/confirmation of pesticides and their metabolites. Recent developments in analytical instrumentation have enabled coupling of ultra-performance liquid chromatography (UPLC) and fast gas chromatography (GC) with MS detectors, and faster analysis for a greater number of pesticides. The newly developed "ambient-ionization" MS techniques (e.g., desorption electrospray ionization, DESI, and direct analysis in real time, DART) hyphenated with high-resolution MS platforms without liquid chromatography separation, and sometimes with minimum pre-treatment, have shown potential for pesticide residue screening. The recently introduced Orbitrap mass spectrometers can provide high resolving power and mass accuracy, to tackle complex analytical problems involved in pesticide residue analysis.
Keywords: food and water; liquid and gas chromatography; mass spectrometry; pesticides.
Copyright © 2010 Wiley Periodicals, Inc.
Similar articles
-
Time of flight mass spectrometry applied to the liquid chromatographic analysis of pesticides in water and food.Mass Spectrom Rev. 2006 Nov-Dec;25(6):866-80. doi: 10.1002/mas.20094. Mass Spectrom Rev. 2006. PMID: 16752429 Review.
-
Analysis of pesticide residues using the Quick Easy Cheap Effective Rugged and Safe (QuEChERS) pesticide multiresidue method in combination with gas and liquid chromatography and tandem mass spectrometric detection.Anal Bioanal Chem. 2007 Nov;389(6):1697-714. doi: 10.1007/s00216-007-1610-7. Epub 2007 Oct 2. Anal Bioanal Chem. 2007. PMID: 17909760
-
Analysis of macrolide antibiotics, using liquid chromatography-mass spectrometry, in food, biological and environmental matrices.Mass Spectrom Rev. 2009 Jan-Feb;28(1):50-92. doi: 10.1002/mas.20189. Mass Spectrom Rev. 2009. PMID: 18785191 Review.
-
Quantification, confirmation and screening capability of UHPLC coupled to triple quadrupole and hybrid quadrupole time-of-flight mass spectrometry in pesticide residue analysis.J Mass Spectrom. 2010 Apr;45(4):421-36. doi: 10.1002/jms.1728. J Mass Spectrom. 2010. PMID: 20301091
-
Analysis of pesticides in water by liquid chromatography-tandem mass spectrometric techniques.Mass Spectrom Rev. 2006 Nov-Dec;25(6):900-16. doi: 10.1002/mas.20093. Mass Spectrom Rev. 2006. PMID: 16705628 Review.
Cited by
-
Structural Elucidation of Agrochemical Metabolic Transformation Products Based on Infrared Ion Spectroscopy to Improve In Silico Toxicity Assessment.Chem Res Toxicol. 2024 Jan 15;37(1):81-97. doi: 10.1021/acs.chemrestox.3c00316. Epub 2023 Dec 20. Chem Res Toxicol. 2024. PMID: 38118149 Free PMC article.
-
Simultaneous analysis of herbicides pendimethalin, oxyfluorfen, imazethapyr and quizalofop-p-ethyl by LC-MS/MS and safety evaluation of their harvest time residues in peanut (Arachis hypogaea L.).J Food Sci Technol. 2015 Jul;52(7):4001-14. doi: 10.1007/s13197-014-1473-9. Epub 2014 Jul 14. J Food Sci Technol. 2015. PMID: 26139867 Free PMC article.
-
Degradation of the Neonicotinoid Pesticides in the Atmospheric Pressure Ionization Source.J Am Soc Mass Spectrom. 2018 Feb;29(2):373-381. doi: 10.1007/s13361-017-1832-7. Epub 2017 Dec 19. J Am Soc Mass Spectrom. 2018. PMID: 29260456
-
Characteristics of Ion Activation and Collision Induced Dissociation Using Digital Ion Trap Technology.J Am Soc Mass Spectrom. 2016 Aug;27(8):1351-6. doi: 10.1007/s13361-016-1407-z. Epub 2016 May 5. J Am Soc Mass Spectrom. 2016. PMID: 27150507
-
Structural Elucidation of Agrochemicals and Related Derivatives Using Infrared Ion Spectroscopy.Environ Sci Technol. 2022 Nov 15;56(22):15563-15572. doi: 10.1021/acs.est.2c03210. Epub 2022 Oct 10. Environ Sci Technol. 2022. PMID: 36214158 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous