Crystalloid versus colloid for circulatory preload for epidural caesarean section
- PMID: 2474257
- DOI: 10.1111/j.1365-2044.1989.tb11369.x
Crystalloid versus colloid for circulatory preload for epidural caesarean section
Abstract
Sixty mothers were randomly allocated to receive either 2 litres of crystalloid or 1 litre of colloid solution (hydroxyethyl starch) in order to preload the circulation prior to elective Caesarean section under epidural anaesthesia. There were no differences in the incidence of hypotension, degree of haemodilution, umbilical cord blood gas tensions or umbilical blood osmolalities between the two groups.
Comment in
-
Hypotension and epidural for caesarean section.Anaesthesia. 1990 Jan;45(1):69. doi: 10.1111/j.1365-2044.1990.tb14535.x. Anaesthesia. 1990. PMID: 2316855 No abstract available.