Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Nov;148(5):2060-9.
doi: 10.1016/j.jtcvs.2014.03.027. Epub 2014 Mar 20.

Effect of aortic aneurysm replacement on outcomes after bicuspid aortic valve surgery: validation of contemporary guidelines

Affiliations
Free article
Comparative Study

Effect of aortic aneurysm replacement on outcomes after bicuspid aortic valve surgery: validation of contemporary guidelines

Daniel Rinewalt et al. J Thorac Cardiovasc Surg. 2014 Nov.
Free article

Abstract

Objective: Bicuspid aortic valve (BAV) disease is associated with aortic dilatation and aneurysm (AN) formation. The American College of Cardiology/American Heart Association (ACC/AHA) 2006 guidelines recommend replacement of the ascending aorta for an aortic diameter (AD)> 45 mm in patients undergoing aortic valve replacement (AVR). We evaluated the outcomes of AVR and AVR with aortic replacement (AVR/AN).

Methods: We retrospectively reviewed (2004-2011) the data from 456 patients with BAV and compared the morbidity and mortality between the AVR and AVR/AN groups and 3 subgroups: AVR with an AD<45 mm; AVR/AN with an AD of 45 to 49 mm; and AVR/AN with an AD of ≥50 mm. Propensity score matching was used to reduce bias.

Results: Of the 456 patients, 250 (55%) underwent AVR and 206 (45%) AVR/AN, with 98% compliance with the current guidelines. The overall 30-day mortality was 0.9%. The AVR AD<45-mm group had adjusted short- and medium-term survival similar to that of the AVR/AN AD 45- to 49-mm and AVR/AN AD≥50-mm groups, with a 30-day mortality of 0.8%, 0%, and 1.9%, respectively (P=.41). The propensity score-matched AVR/AN AD≥50-mm group had significantly greater rates of reintubation than either the AVR AD<45-mm (P=.012) or AVR/AN AD 45- to 49-mm (P=.04) group and greater rates of prolonged ventilation (P=.022) than the AVR AD<45-mm group. No significant differences were found in reoperation or myocardial infarction among the subgroups.

Conclusions: In patients with undergoing AVR, no increase was seen in morbidity or mortality when adding aortic replacement with an AD of 45 to 49 mm, in accordance with the 2006 ACC/AHA guidelines, although the AVR/AN AD≥50-mm group had a greater risk of respiratory complications. Our findings indicate that compliance with the ACC/AHA guidelines is safe in select centers.

PubMed Disclaimer

Comment in

Publication types

MeSH terms