Comparative Study
. 2014 Jun;85(3):299-304.
doi: 10.3109/17453674.2014.913226. Epub 2014 Apr 23.

Distal tibia fractures: locked or non-locked plating? A systematic review of outcomes

Affiliations
Comparative Study

Distal tibia fractures: locked or non-locked plating? A systematic review of outcomes

Amrit S Khalsa et al. Acta Orthop. 2014 Jun.

Abstract

Background and purpose: Although plating is considered to be the treatment of choice in distal tibia fractures, controversies abound regarding the type of plating for optimal fixation. We conducted a systematic review to evaluate and compare the outcomes of locked plating and non-locked plating in treatment of distal tibia fractures.

Patients and methods: A systematic review was conducted using PubMed to identify articles on the outcomes of plating in distal tibia fractures that were published up to June 2012. We included English language articles involving a minimum of 10 adult cases with acute fractures treated using single-plate, minimally invasive techniques. Study-level binomial regression on the pooled data was conducted to determine the effect of locking status on different outcomes, adjusted for age, sex, and other independent variables.

Results: 27 studies met the inclusion criteria and were included in the final analysis of 764 cases (499 locking, 265 non-locking). Based on descriptive analysis only, delayed union was reported in 6% of cases with locked plating and in 4% of cases with non-locked plating. Non-union was reported in 2% of cases with locked plating and 3% of cases with non-locked plating. Comparing locked and non-locked plating, the odds ratio (OR) for reoperation was 0.13 (95% CI: 0.03-0.57) and for malalignment it was 0.10 (95% CI: 0.02-0.42). Both values were statistically significant.

Interpretation: This study showed that locked plating reduces the odds of reoperation and malalignment after treatment for acute distal tibia fracture. Future studies should accurately assess causality and the clinical and economic impact of these findings.

PubMed Disclaimer

Figures

None
Flow chart showing the steps of the literature search.

References

    1. Ahmad MA, Sivaraman A, Zia A, Rai A, Patel AD. Percutaneous locking plates for fractures of the distal tibia: our exper... . J Trauma Acute Care Surg. 2012;72(2):E81–7. - PubMed
    1. Aksekili MA, Celik I, Arslan AK, Kalkan T, Ugurlu M. The results of minimally invasive percutaneous plate osteosynthesis (MIP... . Acta Orthop Traumatol Turc. 2012;46(3):161–7. - PubMed
    1. Babis GC, Kontovazenitis P, Evangelopoulos DS, Tsailas P, Nikolopoulos K, Soucacos PN. Distal tibial fractures treated with hybrid external fixation . Injury. 2010;41(3):253–8. - PubMed
    1. Bahari S, Lenehan B, Khan H, McElwain JP. Minimally invasive percutaneous plate fixation of distal tibia fractures . Acta Orthop Belg. 2007;73(5):635–40. - PubMed
    1. Borens O, Kloen P, Richmond J, Roederer G, Levine DS, Helfet DL. Minimally invasive treatment of pilon fractures with a low profile plate... . Arch Orthop Trauma Surg. 2009;129(5):649–59. - PubMed