Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2014 Jun:177:29-33.
doi: 10.1016/j.ejogrb.2014.03.025. Epub 2014 Apr 12.

Diagnostic accuracy of endometrial thickness for the detection of intra-uterine pathologies and appropriateness of performed hysteroscopies among asymptomatic postmenopausal women

Affiliations
Observational Study

Diagnostic accuracy of endometrial thickness for the detection of intra-uterine pathologies and appropriateness of performed hysteroscopies among asymptomatic postmenopausal women

L Giannella et al. Eur J Obstet Gynecol Reprod Biol. 2014 Jun.

Abstract

Objective: To measure the diagnostic accuracy of endometrial thickness for the detection of intra-uterine pathologies among asymptomatic postmenopausal women, and to test the diagnostic accuracy and appropriateness of performed hysteroscopies.

Study design: Prospective study of 268 asymptomatic postmenopausal women with endometrial thickness ≥4 mm referred to diagnostic hysteroscopy. The diagnostic accuracy of various endometrial thickness cut-off values was tested. Histological and hysteroscopic results were compared to measure the diagnostic accuracy of outpatient hysteroscopies.

Results: No endometrial thickness cut-off values had optimal diagnostic accuracy [positive likelihood ratio (LR+) >10 and negative likelihood ratio (LR-) <0.1]. The best endometrial thickness cut-off value for the detection of all intra-uterine pathologies was ≥8 mm (LR+ 10.05 and LR- 0.22). An endometrial thickness cut-off value ≥10 mm did not miss any cases of endometrial cancer. The success rate of diagnostic hysteroscopy was 89%, but 97% of these revealed a benign intra-uterine pathology. The diagnostic accuracy of hysteroscopy was optimal for all intra-uterine pathologies, except endometrial hyperplasia (LR- 0.52).

Conclusion: Using an endometrial thickness cut-off value ≥4 mm, only 3% of performed hysteroscopies were useful for the detection of pre-malignant or malignant lesions. Despite the finding that endometrial thickness did not show optimal diagnostic accuracy, using the best cut-off value (≥8 mm) may be helpful to decrease the number of false-positive results. No cases of endometrial cancer were diagnosed in asymptomatic postmenopausal women with endometrial thickness <10mm.

Keywords: Appropriateness; Asymptomatic postmenopausal women; Diagnostic accuracy; Endometrial thickness; Hysteroscopy; Intra-uterine pathology.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources