Properties of ultrasonically marked leads
- PMID: 2476761
- DOI: 10.1111/j.1540-8159.1989.tb05051.x
Properties of ultrasonically marked leads
Abstract
We have developed an ultrasonic marking system for pacing leads and the electrophysiological study of catheters. The aim of this study was to evaluate the accuracy of our system, its usability in the measurement of performance of implanted leads, and to investigate the potential of electrical shock and ultrasonic hazard. The measurements have shown that different applications require specific electronic design, involving some compromise between accuracy and sensitivity. A higher sensitivity at the beginning of the ultrasonically guided cardiac lead implantation yields poorer accuracy. Quantitative measurements show that accuracy can be subsequently improved by reduction of sensitivity of the marking system. The transponder marking circuit is better suited for general use and the passive electronic circuit is better suited for multiple electrode electrophysiological studies. Experiments concerning electrical safety show that in the worst failure case, the energy of the marking system released within the heart is less than 10(-9) J per pulse within the pacing frequency spectrum and the current was below 50 microamperes. Ultrasound intensities were within the safety limits set by international and national organizations. The experiments using the marking system for detection of the pacing lead failure showed that the system can yield an early warning of the lead malfunction. The system can significantly reduce the exposure of the medical staff and the patients to x rays as well as improve patient follow-up accuracy.
Similar articles
-
Clinical performance of steroid-eluting pacing leads with 1.2-mm2 electrodes.Pacing Clin Electrophysiol. 1997 Nov;20(11):2799-809. doi: 10.1111/j.1540-8159.1997.tb05438.x. Pacing Clin Electrophysiol. 1997. PMID: 9392811
-
Telemetry guided pacemaker programming: impact of output amplitude and the use of low threshold leads on projected pacemaker longevity.Pacing Clin Electrophysiol. 1998 Nov;21(11 Pt 1):2055-63. doi: 10.1111/j.1540-8159.1998.tb01123.x. Pacing Clin Electrophysiol. 1998. PMID: 9826856
-
First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices.J Am Coll Cardiol. 2007 Aug 28;50(9):877-83. doi: 10.1016/j.jacc.2007.04.081. Epub 2007 Aug 13. J Am Coll Cardiol. 2007. PMID: 17719475
-
Pacemaker leads: performance and progress.Am J Cardiol. 1999 Mar 11;83(5B):187D-191D. doi: 10.1016/s0002-9149(98)01022-4. Am J Cardiol. 1999. PMID: 10089864 Review.
-
Innovations in pulse generators and lead systems: balancing complexity with clinical benefit and long-term results.Am Heart J. 1994 Apr;127(4 Pt 2):1010-21. doi: 10.1016/0002-8703(94)90080-9. Am Heart J. 1994. PMID: 8160574 Review.
Cited by
-
Acute and chronic high-frequency properties of cardiac pacing and defibrillation leads.Med Biol Eng Comput. 2012 Aug;50(8):827-37. doi: 10.1007/s11517-012-0935-3. Epub 2012 Jun 24. Med Biol Eng Comput. 2012. PMID: 22729359
-
Possibilities of ultrasound catheters.Int J Card Imaging. 1991;6(3-4):277-84. doi: 10.1007/BF01797859. Int J Card Imaging. 1991. PMID: 1919070
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical