Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2014 Jun;23(6):767-74.
doi: 10.1016/j.jse.2014.02.010. Epub 2014 Apr 24.

Shoulder function after surgical treatment of displaced fractures of the humeral shaft: a randomized trial comparing antegrade intramedullary nailing with minimally invasive plate osteosynthesis

Affiliations
Randomized Controlled Trial

Shoulder function after surgical treatment of displaced fractures of the humeral shaft: a randomized trial comparing antegrade intramedullary nailing with minimally invasive plate osteosynthesis

Eduardo Benegas et al. J Shoulder Elbow Surg. 2014 Jun.

Abstract

Background: Minimally invasive plate osteosynthesis for humeral shaft fractures has been described recently, but there are no randomized studies comparing the clinical results for shoulder function between this technique and locking intramedullary nailing.

Methods: A prospective randomized study was performed. Forty-one humeral shaft fractures (40 patients) were randomized to be treated with a minimally invasive plate (n = 21) or a locking intramedullary nail (n = 19). Clinical and radiographic outcome assessments were conducted at 1 year postoperatively. Shoulder function was the primary outcome, as measured by the University of California, Los Angeles Shoulder Scale. Elbow function was measured by the Broberg-Morrey score, and fracture consolidation and complications were the main secondary outcomes.

Results: At 1 year postoperatively, no significant difference was found with regard to shoulder function according to the University of California, Los Angeles scale between the minimally invasive plate and locking intramedullary nail (31.4 points vs 31.2 points, P = .98). There was also no difference in elbow function (94.8 points vs 94.1 points, P = .96). Complications were similar between the groups, without significant differences regarding infection (P > .99), symptomatic shoulder stiffness (P = .488), and neurapraxia of the lateral cutaneous nerve of the forearm (P = .475). Fracture union was achieved in all but 1 patient (2.4%) in the intramedullary nail group within 1 year after the surgical procedure.

Conclusion: There is no significant difference in shoulder function between antegrade intramedullary nailing and minimally invasive plate osteosynthesis for the treatment of displaced humeral shaft fractures, despite the limited power of our study.

Keywords: Shoulder; bone plates; fracture fixation; humeral shaft fractures; intramedullary nail; shoulder function.

PubMed Disclaimer

Publication types

LinkOut - more resources