Analysis of microvascular permeability to macromolecules by video-image digital processing
- PMID: 2477668
- DOI: 10.1016/0026-2862(89)90028-9
Analysis of microvascular permeability to macromolecules by video-image digital processing
Abstract
The dynamics of macromolecular transport across microvascular walls were studied in the hamster cheek pouch by intravital fluorescence microscopy. A graded series of fluorescein isothiocyanate-labeled dextrans (FITC-Dx) of 20,000-70,000 MW was used as macromolecular tracers. The time-dependent extravasation of FITC-Dxs was videotaped for about 2.5 hr to allow for tracer equilibration in the interstitial space. Permeation of macromolecules from individual microvessels was quantified by digital video-image processing. Histograms of the light intensity distributions for selected fields at various times were measured and used to construct integral optical density-time profiles of the extravasated fluorochromes for particular leaky sites. A nonlinear regression algorithm was employed to determine the effective microvascular permeability (P) for the macromolecules studied using a one-dimensional two-compartmental diffusion model and a step change in macromolecular concentration at the boundary. The calculated P's (X 10(-8) cm/sec) were 47.8 +/- 8.7 for FITC-Dx 20; 31.7 +/- 5.9 for FITC-Dx 40, and 17.5 +/- 4.1 for FITC-Dx 70. Our values are comparable to those obtained by whole organ techniques. The observed differences can be explained by explicit consideration of interstitial resistance in the calculations.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources