Validation of semi-automatic scoring of dicentric chromosomes after simulation of three different irradiation scenarios
- PMID: 24776911
- DOI: 10.1097/HP.0000000000000077
Validation of semi-automatic scoring of dicentric chromosomes after simulation of three different irradiation scenarios
Abstract
Large scale radiological emergencies require high throughput techniques of biological dosimetry for population triage in order to identify individuals indicated for medical treatment. The dicentric assay is the "gold standard" technique for the performance of biological dosimetry, but it is very time consuming and needs well trained scorers. To increase the throughput of blood samples, semi-automation of dicentric scoring was investigated in the framework of the MULTIBIODOSE EU FP7 project, and dose effect curves were established in six biodosimetry laboratories. To validate these dose effect curves, blood samples from 33 healthy donors (>10 donors/scenario) were irradiated in vitro with ⁶⁰Co gamma rays simulating three different exposure scenarios: acute whole body, partial body, and protracted exposure, with three different doses for each scenario. All the blood samples were irradiated at Ghent University, Belgium, and then shipped blind coded to the participating laboratories. The blood samples were set up by each lab using their own standard protocols, and metaphase slides were prepared to validate the calibration curves established by semi-automatic dicentric scoring. In order to achieve this, 300 metaphases per sample were captured, and the doses were estimated using the newly formed dose effect curves. After acute uniform exposure, all laboratories were able to distinguish between 0 Gy, 0.5 Gy, 2.0, and 4.0 Gy (p < 0.001), and, in most cases, the dose estimates were within a range of ± 0.5 Gy of the given dose. After protracted exposure, all laboratories were able to distinguish between 1.0 Gy, 2.0 Gy, and 4.0 Gy (p < 0.001), and here also a large number of the dose estimates were within ± 0.5 Gy of the irradiation dose. After simulated partial body exposure, all laboratories were able to distinguish between 2.0 Gy, 4.0 Gy, and 6.0 Gy (p < 0.001). Overdispersion of the dicentric distribution enabled the detection of the partial body samples; however, this result was clearly dose-dependent. For partial body exposures, only a few dose estimates were in the range of ± 0.5 Gy of the given dose, but an improvement could be achieved with higher cell numbers. The new method of semi-automation of the dicentric assay was introduced successfully in a network of six laboratories. It is therefore concluded that this method can be used as a high-throughput screening tool in a large-scale radiation accident.
Similar articles
-
Automatic scoring of dicentric chromosomes as a tool in large scale radiation accidents.Mutat Res. 2013 Aug 30;756(1-2):174-83. doi: 10.1016/j.mrgentox.2013.05.013. Epub 2013 May 23. Mutat Res. 2013. PMID: 23707243
-
Web-based scoring of the dicentric assay, a collaborative biodosimetric scoring strategy for population triage in large scale radiation accidents.Radiat Environ Biophys. 2014 May;53(2):241-54. doi: 10.1007/s00411-014-0519-8. Epub 2014 Feb 21. Radiat Environ Biophys. 2014. PMID: 24557539
-
Biological dosimetry by automated dicentric scoring in a simulated emergency.Radiat Res. 2013 May;179(5):557-69. doi: 10.1667/RR3196.1. Epub 2013 Apr 5. Radiat Res. 2013. PMID: 23560627
-
Cytogenetic damage analysed by the dicentric assay.Ann Ist Super Sanita. 2009;45(3):251-9. Ann Ist Super Sanita. 2009. PMID: 19861729 Review.
-
Usefulness and limits of biological dosimetry based on cytogenetic methods.Radiat Prot Dosimetry. 2005;115(1-4):448-54. doi: 10.1093/rpd/nci061. Radiat Prot Dosimetry. 2005. PMID: 16381765 Review.
Cited by
-
Fabric Phase Sorptive Extraction-A Metabolomic Preprocessing Approach for Ionizing Radiation Exposure Assessment.J Proteome Res. 2019 Aug 2;18(8):3020-3031. doi: 10.1021/acs.jproteome.9b00142. Epub 2019 May 22. J Proteome Res. 2019. PMID: 31090424 Free PMC article.
-
Comparing seven mitogens with PHA-M for improved lymphocyte stimulation in dicentric chromosome analysis for biodosimetry.Radiat Prot Dosimetry. 2016 Feb;168(2):235-41. doi: 10.1093/rpd/ncv286. Epub 2015 May 9. Radiat Prot Dosimetry. 2016. PMID: 25958413 Free PMC article.
-
Machine learning approach for quantitative biodosimetry of partial-body or total-body radiation exposures by combining radiation-responsive biomarkers.Sci Rep. 2023 Jan 18;13(1):949. doi: 10.1038/s41598-023-28130-0. Sci Rep. 2023. PMID: 36653416 Free PMC article.
-
Development of electronic training and telescoring tools to increase the surge capacity of dicentric chromosome scorers for radiological/nuclear mass casualty incidents.Appl Radiat Isot. 2019 Feb;144:111-117. doi: 10.1016/j.apradiso.2018.12.005. Epub 2018 Dec 5. Appl Radiat Isot. 2019. PMID: 30572199 Free PMC article.
-
Dose Variations Using an X-Ray Cabinet to Establish in vitro Dose-Response Curves for Biological Dosimetry Assays.Front Public Health. 2022 May 17;10:903509. doi: 10.3389/fpubh.2022.903509. eCollection 2022. Front Public Health. 2022. PMID: 35655448 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous