Dose estimation using dicentric chromosome assay and cytokinesis block micronucleus assay: comparison between manual and automated scoring in triage mode
- PMID: 24776913
- DOI: 10.1097/HP.0000000000000097
Dose estimation using dicentric chromosome assay and cytokinesis block micronucleus assay: comparison between manual and automated scoring in triage mode
Abstract
In cases of an accidental overexposure to ionizing radiation, it is essential to estimate the individual absorbed dose of a potentially radiation-exposed person. For this purpose, biological dosimetry can be performed to confirm, complement or even replace physical dosimetry when this proves to be unavailable. The most validated biodosimetry techniques for dose estimation are the dicentric chromosome assay, the "gold standard" for individual dose assessment, and cytokinesis-block micronucleus assay. However, both assays are time consuming and require skilled scorers. In case of large-scale accidents, different strategies have been developed to increase the throughput of cytogenetic service laboratories. These are the decrease of cell numbers to be scored for triage dosimetry; the automation of procedures including the scoring of, for example, aberrant chromosomes and micronuclei; and the establishment of laboratory networks in order to enable mutual assistance if necessary. In this study, the authors compared the accuracy of triage mode biodosimetry by dicentric chromosome analysis and the cytokinesis block micronucleus assay performing both the manual and the automated scoring mode. For dose estimation using dicentric chromosome assay of 10 blind samples irradiated up to 6.4 Gy of x-rays, a number of metaphase spreads were analyzed ranging from 20 up to 50 cells for the manual and from 20 up to 500 cells for the automatic scoring mode. For dose estimation based on the cytokinesis block micronucleus assay, the micronucleus frequency in both 100 and 200 binucleated cells was determined by manual and automatic scoring. The results of both assays and scoring modes were compared and analyzed considering the sensitivity, specificity, and accuracy of dose estimation with regard to the discrimination power of clinically relevant binary categories of exposure doses.
Similar articles
-
Cytokinesis-block micronucleus assay by manual and automated scoring: calibration curves and dose prediction.Health Phys. 2014 Jun;106(6):745-9. doi: 10.1097/HP.0000000000000052. Health Phys. 2014. PMID: 24776908
-
RENEB Inter-Laboratory Comparison 2021: The Cytokinesis-Block Micronucleus Assay.Radiat Res. 2023 Jun 1;199(6):571-582. doi: 10.1667/RADE-22-00201.1. Radiat Res. 2023. PMID: 37057983
-
Validation of the cytokinesis-block micronucleus (CBMN) assay for use as a triage biological dosimetry tool.Radiat Prot Dosimetry. 2009 Aug;135(4):232-42. doi: 10.1093/rpd/ncp119. Radiat Prot Dosimetry. 2009. PMID: 19628702
-
The micronucleus assay in radiation accidents.Ann Ist Super Sanita. 2009;45(3):260-4. Ann Ist Super Sanita. 2009. PMID: 19861730 Review.
-
The micronucleus assay as a biological dosimeter of in vivo ionising radiation exposure.Mutagenesis. 2011 Jan;26(1):11-7. doi: 10.1093/mutage/geq078. Mutagenesis. 2011. PMID: 21164177 Review.
Cited by
-
Optimized automated data analysis for the cytokinesis-block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry.Cytometry A. 2016 Jul;89(7):653-62. doi: 10.1002/cyto.a.22887. Epub 2016 Jun 6. Cytometry A. 2016. PMID: 27272602 Free PMC article.
-
The Application of Imaging Flow Cytometry to High-Throughput Biodosimetry.Genome Integr. 2017 Jan 23;8:7. doi: 10.4103/2041-9414.198912. eCollection 2017. Genome Integr. 2017. PMID: 28250914 Free PMC article. Review.
-
Development of high-throughput systems for biodosimetry.Radiat Prot Dosimetry. 2023 Sep 18;199(14):1477-1484. doi: 10.1093/rpd/ncad060. Radiat Prot Dosimetry. 2023. PMID: 37721060 Free PMC article.
-
A machine learning method for improving the accuracy of radiation biodosimetry by combining data from the dicentric chromosomes and micronucleus assays.Sci Rep. 2022 Dec 6;12(1):21077. doi: 10.1038/s41598-022-25453-2. Sci Rep. 2022. PMID: 36473912 Free PMC article.
-
Use of human lymphocyte G0 PCCs to detect intra- and inter-chromosomal aberrations for early radiation biodosimetry and retrospective assessment of radiation-induced effects.PLoS One. 2019 May 6;14(5):e0216081. doi: 10.1371/journal.pone.0216081. eCollection 2019. PLoS One. 2019. PMID: 31059552 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources