Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Oct;12(4):535-42.
doi: 10.1007/s12021-014-9229-2.

Validation of FreeSurfer-estimated brain cortical thickness: comparison with histologic measurements

Affiliations

Validation of FreeSurfer-estimated brain cortical thickness: comparison with histologic measurements

Francesco Cardinale et al. Neuroinformatics. 2014 Oct.

Abstract

FreeSurfer software package automatically estimates the cerebral cortical thickness. Its use is widely accepted, albeit this tool was validated against histologic measurements in only two post-mortem isolated brain MR scans. Indeed, a comparison between histologic measurements and FreeSurfer estimation from in vivo data was never performed. At the "Claudio Munari" Center for Epilepsy and Parkinson Surgery we have included FreeSurfer in our presurgical workflow since 2008, mainly because the automatic reconstruction of the brain surface is useful for carefully planning the surgical resection. We therefore compared cortical thickness values obtained by the automatic software pipeline with manual histologic measurements performed on 27 histologic specimens resected from the corresponding brain regions of the same epileptic subjects. This method-comparison study, including Passing-Bablok regression and Bland-Altman plot analysis, showed a good agreement between FreeSurfer estimation and histologic measurements of cortical thickness. The mean cortical thickness values (±Standard Deviation) obtained with FreeSurfer and histologic measurements were 3.65 mm ± 0.44 and 3.72 mm ± 0.36, respectively (P value = 0.32). Our findings strengthen previous reports on cortical thickness changes as biomarkers of different neurological conditions.

PubMed Disclaimer

References

    1. J Clin Chem Clin Biochem. 1984 Jun;22(6):431-45 - PubMed
    1. PLoS One. 2012;7(6):e38234 - PubMed
    1. Neuroradiology. 2012 Oct;54(10):1065-77 - PubMed
    1. Epilepsia. 2011 Jan;52(1):158-74 - PubMed
    1. Proc Natl Acad Sci U S A. 2000 Sep 26;97(20):11050-5 - PubMed

LinkOut - more resources