. 2014 Apr 18;7(2):309-12.
doi: 10.3980/j.issn.2222-3959.2014.02.20. eCollection 2014.

White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II

Affiliations

White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II

Hamid Gharaee et al. Int J Ophthalmol. .

Abstract

Aim: To determine the normative values of white-to-white corneal diameter with Orbscan II Topography System and to compare right and left eyes data in the normal young population.

Methods: A total of 1001 healthy participants aged 18-45y participated in this observational cross-sectional study. The study population consisted of 616 female and 385 male subjects. The corneal diameter was measured with the Orbscan II. The differences between genders, between right and left eyes and age-related changes were evaluated. Statistical analyses were performed using Student's t-test.

Results: The average white-to-white distance in our study population was recorded as 11.65±0.36 mm (median: 11.60 mm, mode: 11.70 mm, minimum: 10.50 mm and maximum: 13.60 mm). The white-to-white distance was 11.60±0.35 mm in males and 11.71±0.36 mm in females which was statistically different between genders (P<0.01). However, white-to-white distance was not statistically different between right and left eyes. In addition, this parameter decreased with increasing age. Considering 95% confidence interval, corneal diameter less than 10.93 mm and greater than 12.34 mm would be considered as microcornea and megalocornea, respectively based on this study population, using the Orbscan II topography.

Conclusion: Detailed description and analysis of corneal diameter with Orbscan demonstrate that the obtained average value of horizontal white-to-white is higher in male than female and decreases slightly with increasing age. Our data also suggests the cut off values for definition of microcornea and megalocornea, which can be employed with this population.

Keywords: Orbscan II; corneal diameter; normal population; white-to-white.

PubMed Disclaimer

Figures

Figure 1
Figure 1. Correlation between white-to-white diameter and age.

Similar articles

Cited by

References

    1. Wallace DK, Plager DA. Corneal diameter in childhood aphakic glaucoma. J Pediatr Ophthalmol Strabismus. 1996;33(5):230–234. - PubMed
    1. Hoffer KJ. Clinical results using the Holladay 2 intraocular lens power formula. J Cataract Refract Surg. 2000;26(8):1233–1237. - PubMed
    1. Venkataraman A, Mardi SK, Pillai S. Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter. Indian J Ophthalmol. 2010;58(3):219–222. - PMC - PubMed
    1. Vass C, Menapace R, Schmetterer K, Findl O, Rainer G, Steineck I. Prediction of pseudophakic capsular bag diameter based on biometric variables. J Cataract Refract Surg. 1999;25(10):1376–1381. - PubMed
    1. Dong EY, Joo CK. Predictability for proper capsular tension ring size and intraocular lens size. Korean J Ophthalmol. 2001;15(1):22–26. - PubMed

LinkOut - more resources