Three-dimensional contrast enhanced ultrasound score and dynamic contrast-enhanced magnetic resonance imaging score in evaluating breast tumor angiogenesis: correlation with biological factors
- PMID: 24794865
- DOI: 10.1016/j.ejrad.2014.03.027
Three-dimensional contrast enhanced ultrasound score and dynamic contrast-enhanced magnetic resonance imaging score in evaluating breast tumor angiogenesis: correlation with biological factors
Abstract
Objective: To explore the clinical value of three-dimensional contrast enhanced ultrasound (3D-CEUS) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) score systems in evaluating breast tumor angiogenesis by comparing their diagnostic efficacy and correlation with biological factors.
Methods: 3D-CEUS was performed in 183 patients with breast tumors by Esaote Mylab90 with SonoVue (Bracco, Italy), DCE-MRI was performed on a dedicated breast magnetic resonance imaging (DBMRI) system (Aurora Dedicated Breast MRI Systems, USA) with a dedicated breast coil. 3D-CEUS and DCE-MRI score systems were created based on tumor perfusion and vascular characteristics. Microvessel density (MVD), vascular endothelial growth factor (VEGF) and matrix metalloproteinases (MMP-2, MMP-9) expression were measured by immunohistochemistry.
Results: Pathological results showed 35 benign and 148 malignant breast tumors. MVD (P=0.000, r=0.76), VEGF (P=0.000, r=0.55), MMP-2 (P=0.000, r=0.39) and MMP-9 (P=0.000, r=0.41) expression were all significantly different between benignity and malignancy. Regarding 3D-CEUS 4 points as cutoff value, the sensitivity, specificity and accuracy were 85.1%, 94.3% and 86.9%, respectively, and correlated well with MVD (P=0.000, r=0.50), VEGF (P=0.000, r=0.50), MMP-2 (P=0.000, r=0.50) and MMP-9 (P=0.000, r=0.66). Taking DCE-MRI 5 points as cutoff value, the sensitivity, specificity and accuracy were 86.5%, 94.3% and 88.0%, respectively and also correlated well with MVD (P=0.000, r=0.52), VEGF (P=0.000, r=0.44), MMP-2 (P=0.000, r=0.42) and MMP-9 (P=0.000, r=0.35).
Conclusions: 3D-CEUS score system displays inspiring diagnostic performance and good agreement with DCE-MRI scoring. Moreover, both score systems correlate well with MVD, VEGF, MMP-2 and MMP-9 expression, and thus have great potentials in tumor angiogenesis evaluation.
Keywords: Angiogenesis; Biological factors; Breast tumor; Contrast-enhanced ultrasound; Dynamic contrast-enhanced magnetic resonance imaging; Three-dimensional ultrasound.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical