Technology and new fluorescence flow cytometry parameters in hematological analyzers
- PMID: 24797912
- PMCID: PMC6807107
- DOI: 10.1002/jcla.21747
Technology and new fluorescence flow cytometry parameters in hematological analyzers
Abstract
Background: Modern hematological analyzers offer a series of new tests in addition to the differential blood cell count. Here, we provide a short overview of the technique and the new tests included in the hematological analyzers manufactured by the company Sysmex (Kobe, Japan). As introduced here, the resulting new extended blood cell count allows for the quantification of DNA- and RNA-rich, activated and/or precursor leukocyte subpopulations.
Methods: To compare the different methods of blood cell counting, repetitive cell counting is carried out by hematological experts using microscopy and using the XE-5000 hematological analyzer.
Results: The hematological analyzer delivers more-accurate results with respect to normal cells but microscopy is suited better to recognize and count pathological cells.
Conclusion: With the new hematological analyzers, several new hematological tests are made available as screening tools that were not possible previously using standard cell-counting procedures.
Keywords: hematology.
© 2014 Wiley Periodicals, Inc.
Similar articles
-
Performance evaluation of platelet counting by novel fluorescent dye staining in the XN-series automated hematology analyzers.J Clin Lab Anal. 2014 Sep;28(5):341-8. doi: 10.1002/jcla.21691. Epub 2014 Mar 19. J Clin Lab Anal. 2014. PMID: 24648166 Free PMC article.
-
A Comparison of Mindray BC-6800, Sysmex XN-2000, and Beckman Coulter LH750 Automated Hematology Analyzers: A Pediatric Study.J Clin Lab Anal. 2016 Nov;30(6):1128-1134. doi: 10.1002/jcla.21992. Epub 2016 May 17. J Clin Lab Anal. 2016. PMID: 27184780 Free PMC article.
-
Evaluation of automated capillary complete blood counts for routine clinical decision making in a large cohort of hematological patients, using Mindray BC-3000 Plus Auto and Sysmex XE-5000 hematology analyzers.Int J Lab Hematol. 2020 Oct;42(5):565-572. doi: 10.1111/ijlh.13237. Epub 2020 May 19. Int J Lab Hematol. 2020. PMID: 32426940
-
Clinical analyzers. Advances in automated cell counting.Anal Chem. 1999 Jun 15;71(12):363R-365R. doi: 10.1021/a1999911a. Anal Chem. 1999. PMID: 10384793 Review.
-
Application of flow cytometric techniques to veterinary clinical hematology.Vet Clin Pathol. 2002;31(2):72-82. doi: 10.1111/j.1939-165x.2002.tb00284.x. Vet Clin Pathol. 2002. PMID: 12040489 Review.
Cited by
-
Cord blood neutropenia is an independent predictor of early sepsis.J Perinatol. 2017 Nov;37(11):1204-1209. doi: 10.1038/jp.2017.115. Epub 2017 Aug 24. J Perinatol. 2017. PMID: 28837136
-
Intensive care infection score: ICIS discriminates between infected and uninfected critically ill patients in routine intensive care unit practice.Intensive Care Med Exp. 2025 Jun 5;13(1):58. doi: 10.1186/s40635-025-00767-3. Intensive Care Med Exp. 2025. PMID: 40471473 Free PMC article.
-
High Fluorescent Lymphoid Cell Levels Assessed on Initial Blood Count in Newly Diagnosed Multiple Myeloma Carry Prognostic Significance.EJHaem. 2025 Mar 21;6(2):e1095. doi: 10.1002/jha2.1095. eCollection 2025 Apr. EJHaem. 2025. PMID: 40248326 Free PMC article.
-
Assessment of the Reliability of the Sysmex XE-5000 Analyzer to Detect Platelet Clumps.Lab Med. 2016 Aug;47(3):189-94. doi: 10.1093/labmed/lmw016. Epub 2016 Apr 25. Lab Med. 2016. PMID: 27114250 Free PMC article.
-
Clinical chorioamnionitis at term VII: the amniotic fluid cellular immune response.J Perinat Med. 2017 Jul 26;45(5):523-538. doi: 10.1515/jpm-2016-0225. J Perinat Med. 2017. PMID: 27763883 Free PMC article.
References
-
- Ansari‐Lari MA, Kickler TS, Borowitz M. Immature granulocyte measurement using the Sysmex XE‐2100. Relationship to infection and sepsis. Am J Clin Pathol 2003;120:795–799. - PubMed
-
- Furundarena JR, Araiz M, Uranga M, et al. The utility of the Sysmex XE‐2100 analyzer's NEUT‐X and NEUT‐Y parameters for detecting neutrophil dysplasia in myelodysplastic syndromes. Int J Lab Hematol 2010;32:360–366. - PubMed
-
- Fernandes B, Hamaguchi Y. Automated enumeration of immature granulocytes. Am J Clin Pathol 2007;128(3):454–463. - PubMed
-
- di Mario A, Garzia M, Leone F, Arcangeli A, Pagano L, Zini G. Immature platelet fraction (IPF) in hospitalized patients with neutrophilia and suspected bacterial infection. J Infect 2009;59(3):201–206. - PubMed
-
- Information of the Company Sysmex . 2009. Floureszenz Durchflußzytometrie in der Hämatologie (XE5000 Case Manager). Sysmex Austria, Xtra; p1–11.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials