Comparative Study
. 2014 Oct;112(4):834-8.
doi: 10.1016/j.prosdent.2013.12.018. Epub 2014 May 3.

A microstrain comparison of passively fitting screw-retained and cemented titanium frameworks

Affiliations
Comparative Study

A microstrain comparison of passively fitting screw-retained and cemented titanium frameworks

Diego Klee de Vasconcellos et al. J Prosthet Dent. 2014 Oct.

Abstract

Statement of problem: An imprecise fit between frameworks and supporting dental implants in loaded protocols increases the strain transferred to the periimplant bone, which may impair healing or generate microgaps.

Purpose: The purpose of this study was to investigate the microstrain between premachined 1-piece screw-retained frameworks (group STF) and screw-retained frameworks fabricated by cementing titanium cylinders to the prefabricated framework (group CTF). This procedure was developed to correct the misfit between frameworks and loaded implants.

Material and methods: Four internal hexagon cylindrical implants were placed 10 mm apart in a polyurethane block by using the surgical guides of the corresponding implant system. Previously fabricated titanium frameworks (n=10) were divided into 2 groups. In group STF, prefabricated machined frameworks were used (n=5), and, in group CTF, the frameworks were fabricated by using a passive fit procedure, which was developed to correct the misfit between the cast titanium frameworks and supporting dental implants (n=5). Both groups were screw-retained under torque control (10 Ncm). Six strain gauges were placed on the upper surface of the polyurethane block, and 3 strain measurements were recorded for each framework. Data were analyzed with the Student t test (α=.05).

Results: The mean microstrain values between the framework and the implants were significantly higher for group STF (2517 mε) than for group CTF (844 mε) (P<.05).

Conclusions: Complete-arch implant frameworks designed for load application and fabricated by using the passive fit procedure decreased the strain between the frameworks and implants more than 1 piece prefabricated machined frameworks.