Noncontrast perfusion single-photon emission CT/CT scanning: a new test for the expedited, high-accuracy diagnosis of acute pulmonary embolism
- PMID: 24798835
- DOI: 10.1378/chest.13-2090
Noncontrast perfusion single-photon emission CT/CT scanning: a new test for the expedited, high-accuracy diagnosis of acute pulmonary embolism
Abstract
Background: Standard ventilation and perfusion (V˙/Q˙) scintigraphy uses planar images for the diagnosis of pulmonary embolism (PE). To evaluate whether tomographic imaging improves the diagnostic accuracy of the procedure, we compared noncontrast perfusion single-photon emission CT (Q˙-SPECT)/CT scans with planar V˙/Q˙scans in patients at high risk for PE.
Methods: Between 2006 and 2010, most patients referred for diagnosis of PE underwent both Q˙-SPECT/CT scan and planar V˙/Q˙scintigraphy. All scans were reviewed retrospectively by four observers; planar scans were read with modified Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) II and Prospective Investigative Study of Pulmonary Embolism Diagnosis (PISA-PED) criteria. On Q˙-SPECT/CT scan, any wedge-shaped peripheral perfusion defect occupying > 50% of a segment without corresponding pulmonary parenchymal or pleural disease was considered to show PE. The final diagnosis was established with a composite reference standard that included ECG, ultrasound of lower-extremity veins, D-dimer levels, CT pulmonary angiography (when available), and clinical follow-up for at least 3 months.
Results: One hundred six patients with cancer and mean Wells score of 4.4 had sufficient follow-up; 22 patients were given a final diagnosis of PE, and 84 patients were given a final diagnosis of no PE. According to PIOPED II, 13 studies were graded as intermediate probability. Sensitivity and specificity for PE were 50% and 98%, respectively, based on PIOPED II criteria; 86% and 93%, respectively, based on PISA-PED criteria; and 91% and 94%, respectively, based on Q˙-SPECT/CT scan. Seventy-six patients had additional relevant findings on the CT image of the Q˙-SPECT/CT scan.
Conclusions: Noncontrast Q˙-SPECT/CT imaging has a higher accuracy than planar V˙/Q˙imaging based on PIOPED II criteria in patients with cancer and a high risk for PE.
Similar articles
-
[A comparison of ventilation/perfusion single photon emission CT and CT pulmonary angiography for diagnosis of pulmonary embolism].Zhonghua Jie He He Hu Xi Za Zhi. 2013 Mar;36(3):177-81. Zhonghua Jie He He Hu Xi Za Zhi. 2013. PMID: 23856139 Chinese.
-
The Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis.Respiration. 2015;90(5):393-401. doi: 10.1159/000439543. Epub 2015 Sep 30. Respiration. 2015. PMID: 26418469
-
Is a lung perfusion scan obtained by using single photon emission computed tomography able to improve the radionuclide diagnosis of pulmonary embolism?Nucl Med Commun. 2002 Nov;23(11):1107-13. doi: 10.1097/00006231-200211000-00011. Nucl Med Commun. 2002. PMID: 12411840 Clinical Trial.
-
V/Q SPECT and computed tomographic pulmonary angiography.Semin Nucl Med. 2010 Nov;40(6):426-41. doi: 10.1053/j.semnuclmed.2010.08.001. Semin Nucl Med. 2010. PMID: 20920633 Review.
-
Clinical utility of perfusion (Q)-single-photon emission computed tomography (SPECT)/CT for diagnosing pulmonary embolus (PE) in COVID-19 patients with a moderate to high pre-test probability of PE.Eur J Nucl Med Mol Imaging. 2021 Mar;48(3):794-799. doi: 10.1007/s00259-020-05043-y. Epub 2020 Sep 22. Eur J Nucl Med Mol Imaging. 2021. PMID: 32959115 Free PMC article. Review.
Cited by
-
Dual-energy CT (DECT) lung perfusion in pulmonary hypertension: concordance rate with V/Q scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (CTEPH).Eur Radiol. 2018 Dec;28(12):5100-5110. doi: 10.1007/s00330-018-5467-2. Epub 2018 May 30. Eur Radiol. 2018. PMID: 29846802
-
Software-Based Hybrid Perfusion SPECT/CT Provides Diagnostic Accuracy When Other Pulmonary Embolism Imaging Is Indeterminate.Nucl Med Mol Imaging. 2015 Dec;49(4):303-11. doi: 10.1007/s13139-015-0359-8. Epub 2015 Aug 8. Nucl Med Mol Imaging. 2015. PMID: 26550050 Free PMC article.
-
Investigation of perfusion defects by Q-SPECT/CT in patients with mild-to-moderate course of COVID-19 and low clinical probability for pulmonary embolism.Ann Nucl Med. 2021 Oct;35(10):1117-1125. doi: 10.1007/s12149-021-01647-y. Epub 2021 Jun 25. Ann Nucl Med. 2021. PMID: 34173212 Free PMC article.
-
To everything there is a season: taxonomy of approaches to the performance of lung scintigraphy in the era of COVID-19.Eur J Nucl Med Mol Imaging. 2021 Mar;48(3):666-669. doi: 10.1007/s00259-020-05100-6. Eur J Nucl Med Mol Imaging. 2021. PMID: 33159223 Free PMC article. No abstract available.
-
Evaluation of iron oxide nanoparticle micelles for magnetic particle imaging (MPI) of thrombosis.PLoS One. 2015 Mar 6;10(3):e0119257. doi: 10.1371/journal.pone.0119257. eCollection 2015. PLoS One. 2015. PMID: 25746677 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical