Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2014 Sep;87(1041):20140105.
doi: 10.1259/bjr.20140105. Epub 2014 May 6.

Dosimetric audit in brachytherapy

Affiliations
Review

Dosimetric audit in brachytherapy

A L Palmer et al. Br J Radiol. 2014 Sep.

Abstract

Dosimetric audit is required for the improvement of patient safety in radiotherapy and to aid optimization of treatment. The reassurance that treatment is being delivered in line with accepted standards, that delivered doses are as prescribed and that quality improvement is enabled is as essential for brachytherapy as it is for the more commonly audited external beam radiotherapy. Dose measurement in brachytherapy is challenging owing to steep dose gradients and small scales, especially in the context of an audit. Several different approaches have been taken for audit measurement to date: thimble and well-type ionization chambers, thermoluminescent detectors, optically stimulated luminescence detectors, radiochromic film and alanine. In this work, we review all of the dosimetric brachytherapy audits that have been conducted in recent years, look at current audits in progress and propose required directions for brachytherapy dosimetric audit in the future. The concern over accurate source strength measurement may be essentially resolved with modern equipment and calibration methods, but brachytherapy is a rapidly developing field and dosimetric audit must keep pace.

PubMed Disclaimer

References

    1. NHS England. Clinical audit. [about 1 pp.]. Cited 21 January 2014. Available from: http://www.england.nhs.uk/ourwork/qual-clin-lead/clinaudit/
    1. EORTC. Global Clinical Trials Quality Assurance of Radiation Therapy Harmonisation Group. Cited 21 January 2014. Available from: http://rtqaharmonisation.org/
    1. Pattersen MN, Aird E, Olsen DR. Quality assurance of dosimetry and the impact on sample size in randomized clinical trials. Radiother Oncol 2008; 86: 195–9. doi: 10.1016/j.radonc.2007.07.001 - DOI - PubMed
    1. IAEA QUATRO (Quality assurance Team for Radiation Oncology). Comprehensive audits of radiotherapy practices: a tool for quality improvement. Vienna, Austria: IAEA; 2007.
    1. M.D. Anderson Dosimetry Laboratory. Radiological Physics Centre. Cited 21 January 2014. Available from: http://rpc.mdanderson.org/RPC/home.htm