Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Jun;21(6):812-6.
doi: 10.1016/j.acra.2014.03.007.

Visualization of lenticulostriate arteries at 3T: Optimization of slice-selective off-resonance sinc pulse-prepared TOF-MRA and its comparison with flow-sensitive black-blood MRA

Affiliations
Comparative Study

Visualization of lenticulostriate arteries at 3T: Optimization of slice-selective off-resonance sinc pulse-prepared TOF-MRA and its comparison with flow-sensitive black-blood MRA

Sachi Okuchi et al. Acad Radiol. 2014 Jun.

Abstract

Rationale and objectives: To optimize visualization of lenticulostriate artery (LSA) by time-of-flight (TOF) magnetic resonance angiography (MRA) with slice-selective off-resonance sinc (SORS) saturation transfer contrast pulses and to compare capability of optimal TOF-MRA and flow-sensitive black-blood (FSBB) MRA to visualize the LSA at 3T.

Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all the subjects. TOF-MRA was optimized in 20 subjects by comparing SORS pulses of different flip angles: 0, 400°, and 750°. Numbers of LSAs were counted. The optimal TOF-MRA was compared to FSBB-MRA in 21 subjects. Images were evaluated by the numbers and length of visualized LSAs.

Results: LSAs were significantly more visualized in TOF-MRA with SORS pulses of 400° than others (P < .003). When the optimal TOF-MRA was compared to FSBB-MRA, the visualization of LSA using FSBB (mean branch numbers 11.1, 95% confidence interval (CI) 10.0-12.1; mean total length 236 mm, 95% CI 210-263 mm) was significantly better than using TOF (4.7, 95% CI 4.1-5.3; 78 mm, 95% CI 67-89 mm) for both numbers and length of the LSA (P < .0001).

Conclusions: LSA visualization was best with 400° SORS pulses for TOF-MRA but FSBB-MRA was better than TOF-MRA, which indicates its clinical potential to investigate the LSA on a 3T magnetic resonance imaging.

Keywords: Lenticulostriate artery; MR angiography; flow-sensitive black-blood; saturation transfer contrast; slice-selective off-resonance sinc pulse.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources