Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Mar-Apr;40(2):171-4.
doi: 10.1590/s1806-37132014000200011.

Utility of Asthma Control Questionnaire 7 in the assessment of asthma control

[Article in English, Portuguese]
Affiliations

Utility of Asthma Control Questionnaire 7 in the assessment of asthma control

[Article in English, Portuguese]
Mariana Nadal Cardoso et al. J Bras Pneumol. 2014 Mar-Apr.

Abstract

Our objective was to evaluate the reproducibility of Asthma Control Questionnaire 7 (ACQ-7) in asthma patients, comparing our results against those obtained with the Global Initiative for Asthma (GINA) criteria. We evaluated 52 patients. Patients completed the ACQ-7, underwent spirometry, and were clinically assessed to determine the level of asthma control according to the GINA criteria, in two visits, 15 days apart. The ACQ-7 cutoff for uncontrolled asthma was a score of 1.5. The ACQ-7 showed good reproducibility, with a correlation coefficient of 0.73. The ACQ-7 identified a greater number of patients with uncontrolled asthma than did the GINA criteria; according to the GINA criteria, 47 patients (90.4%) presented with partially controlled asthma.

Nosso objetivo foi avaliar a reprodutibilidade do Asthma Control Questionnaire 7 (ACQ-7) em asmáticos e comparar os resultados com os critérios de controle da Global Initiative for Asthma (GINA). Foram avaliados 52 pacientes em duas visitas com intervalo de 15 dias entre si. Os pacientes responderam o ACQ-7, realizaram espirometria e foram avaliados clinicamente para verificar o controle da asma de acordo com a GINA nas duas visitas. Em relação ao ACQ-7, o ponto de corte para asma não controlada foi definido em 1,5. Os resultados de ACQ-7 demonstraram boa reprodutibilidade, com coeficiente de correlação de 0,73. O ACQ-7 identificou um maior número de pacientes com asma não controlada em relação aos critérios da GINA; segundo os critérios GINA, 47 pacientes (90,4%) tinham asma parcialmente controlada.

PubMed Disclaimer

Figures

Figure 1
Figure 1. Correlation between the Asthma Control Questionnaire 7 (ACQ-7) scores obtained in the initial visit and those obtained 15 days later in the 52 patients studied. r = 0.73; 95% CI: 0.58-0.83; p < 0.0001.
Figura 1
Figura 1. Correlação dos resultados do Asthma Control Questionnaire 7 (ACQ-7) na visita inicial e na visita 15 dias depois nos 52 pacientes estudados. (r = 0,73; IC95%: 0,58-0,83; p < 0,0001)

Similar articles

Cited by

References

    1. Diretrizes da Sociedade Brasileira de Pneumologia e Tisiologia para o Manejo da Asma. J Bras Pneumol. 2012;38(1):S1–S46.
    1. Kazani S, Israel E. Update in Asthma 2011. Am J Respir Crit Care Med. 2012;186(1):35–40. doi: 10.1164/rccm.201204-0634UP. - DOI - PMC - PubMed
    1. Cloutier MM, Schatz M, Castro M, Clark N, Kelly HW, Mangione-Smith R, et al. Asthma outcomes: composite scores of asthma control. J Allergy Clin Immunol. 2012;129(3 ) Suppl:S24–S33. doi: 10.1016/j.jaci.2011.12.980. - DOI - PMC - PubMed
    1. Leite M, Ponte EV, Petroni J, D'Oliveira A, Pizzichini E, Cruz AA. Evaluation of the asthma control questionnaire validated for use in Brazil. J Bras Pneumol. 2008;34(10):756–763. doi: 10.1590/S1806-37132008001000002. - DOI - PubMed
    1. Global Initiative for Asthma - GINA . Global Strategy for Asthma Management and Prevention. Bethesda: Global Initiative for Asthma; [[cited 2013 Nov 11]]. 2013. a Available from: www.ginaasthma.org.