Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Sep;11(5):496-502.
doi: 10.3109/15412555.2014.898037. Epub 2014 May 15.

Prevalence of overestimation or underestimation of the functional capacity using MRC score as compared to 6-minute walk test in patients with cardio-respiratory disorders

Affiliations
Free article
Comparative Study

Prevalence of overestimation or underestimation of the functional capacity using MRC score as compared to 6-minute walk test in patients with cardio-respiratory disorders

Etienne Callens et al. COPD. 2014 Sep.
Free article

Abstract

Objectives: The first objective of our study was to assess whether patients diagnosed with cardio-respiratory disorders report overestimation or underestimation on recall (Medical Research Council (MRC) dyspnea scale) of their true functional capacity (walked distance during a 6-minute walk test (6MWT)). The second objective was to assess whether the measurement of breathlessness at the end of a 6MWT (Borg score) may help to identify dyspneic patients on recall.

Methods: The 6MWTs of 746 patients aged from 40 to 80 years who were diagnosed with either chronic obstructive pulmonary disease (COPD, n = 355), diffuse parenchymal lung disease (n = 140), pulmonary vascular diseases (n = 188) or congestive heart failure (n = 63) were selected from a prospective Clinical Database Warehouse.

Results: The percentage of patients who overestimated (MRC ≤ 2 with distance < lower limit of normal (LLN), 61/746, 8%; 95% confidence interval (CI): 6 to 10%) or underestimated (MRC > 2 with distance ≥LLN, 121/746, 16%; 95%CI: 14 to 19%) on recall their capacity was elevated. The overestimation seemed related to self-limitation, while the underestimation seemed related to patients who "work through" their breathing discomfort. These two latter groups of patients were mainly diagnosed with COPD. A Borg dyspnea score >3 (upper limit of normal) at the end of the 6MWT had 84% specificity for the prediction of a MRC score >1.

Conclusion: Almost one fourth of patients suffering from cardio-pulmonary disorders overestimate or underestimate on recall their true functional capacity. An elevated Borg dyspnea score at the end of the 6MWT has a good specificity to predict dyspnea on recall.

Keywords: activity-related dyspnea; chronic heart failure; chronic obstructive pulmonary disease; diffuse parenchymal lung disease; pulmonary vascular disease.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources