Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models
- PMID: 24835549
- DOI: 10.1902/jop.2014.140107
Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models
Abstract
Background: Occlusal overloading causes peri-implant bone resorption. Previous studies examined stress distribution in alveolar bone around commercial implants using three-dimensional (3D) finite element analysis. However, the commercial implants contained some different designs. The purpose of this study is to reveal the effect of the target design on peri-implant bone stress and abutment micromovement.
Methods: Six 3D implant models were created for different implant-abutment joints: 1) internal joint model (IM); 2) external joint model (EM); 3) straight abutment (SA) shape; 4) tapered abutment (TA) shapes; 5) platform switching (PS) in the IM; and 6) modified TA neck design (reverse conical neck [RN]). A static load of 100 N was applied to the basal ridge surface of the abutment at a 45-degree oblique angle to the long axis of the implant. Both stress distribution in peri-implant bone and abutment micromovement in the SA and TA models were analyzed.
Results: Compressive stress concentrated on labial cortical bone and tensile stress on the palatal side in the EM and on the labial side in the IM. There was no difference in maximum principal stress distribution for SA and TA models. Tensile stress concentration was not apparent on labial cortical bone in the PS model (versus IM). Maximum principal stress concentrated more on peri-implant bone in the RN than in the TA model. The TA model exhibited less abutment micromovement than the SA model.
Conclusion: This study reveals the effects of the design of specific components on peri-implant bone stress and abutment displacement after implant-supported single restoration in the anterior maxilla.
Keywords: Bite force; dental implant-abutment design; dental implants; dental stress analysis; finite element analysis.
Similar articles
-
Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis.Dent Mater. 2012 Nov;28(11):1126-33. doi: 10.1016/j.dental.2012.07.160. Epub 2012 Aug 21. Dent Mater. 2012. PMID: 22920538
-
Regular and platform switching: bone stress analysis varying implant type.J Prosthodont. 2012 Apr;21(3):160-6. doi: 10.1111/j.1532-849X.2011.00801.x. Epub 2012 Feb 28. J Prosthodont. 2012. PMID: 22372756
-
Platform switching: biomechanical evaluation using three-dimensional finite element analysis.Int J Oral Maxillofac Implants. 2011 May-Jun;26(3):482-91. Int J Oral Maxillofac Implants. 2011. PMID: 21691594
-
Angled implant abutments: a practical application of available knowledge.J Am Dent Assoc. 2011 Feb;142(2):150-8. doi: 10.14219/jada.archive.2011.0057. J Am Dent Assoc. 2011. PMID: 21282680 Review.
-
The impact of the type and configuration of abutments and their (repeated) removal on the attachment level and marginal bone.Eur J Oral Implantol. 2012;5 Suppl:S83-90. Eur J Oral Implantol. 2012. PMID: 22834397 Review.
Cited by
-
Biomechanical Analysis of Axial Gradient Porous Dental Implants: A Finite Element Analysis.J Funct Biomater. 2023 Nov 23;14(12):557. doi: 10.3390/jfb14120557. J Funct Biomater. 2023. PMID: 38132811 Free PMC article.
-
Bite force and dental implant treatment: a short review.Med Devices (Auckl). 2017 Jun 27;10:141-148. doi: 10.2147/MDER.S130314. eCollection 2017. Med Devices (Auckl). 2017. PMID: 28721107 Free PMC article. Review.
-
Trabecular Bone Component Assessment under Orthodontic Loads and Movements during Periodontal Breakdown-A Finite Elements Analysis.Dent J (Basel). 2024 Jun 20;12(6):190. doi: 10.3390/dj12060190. Dent J (Basel). 2024. PMID: 38920891 Free PMC article.
-
Finite element analysis of welded titanium bar and poly ether ether ketone bar in maxillary full arch splinted interim prosthesis.Sci Rep. 2025 May 9;15(1):16193. doi: 10.1038/s41598-025-99750-x. Sci Rep. 2025. PMID: 40346189 Free PMC article.
-
Periodontal Breakdown, Orthodontic Movements and Pulpal Ischemia Correlations-A Comparison Between Five Study Methods.J Clin Med. 2024 Nov 22;13(23):7062. doi: 10.3390/jcm13237062. J Clin Med. 2024. PMID: 39685521 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources