Purpose: To assess the feasibility and diagnostic performance of dynamic volumetric computed tomography (CT) angiography with large-area detectors in the detection and classification of endoleaks after endovascular aneurysm repair (EVAR).
Materials and methods: Low-dose dynamic volumetric CT angiography performed with the patient in Fowler position was used to scan the entire stent graft with a 16-cm-area detector during the first follow-up examination after EVAR. There were 39 consecutive patients (36 men and 3 women; mean age, 74 y ± 8.7) examined with approximately 14-20 intermittent scans (temporal resolution, 2 s; scan range, 160 mm). The effective radiation dose, image quality, interobserver and intraobserver agreement for endoleak detection, and time delay between peak enhancement of the aorta and endoleaks were evaluated.
Results: All examinations with the patient in Fowler position enabled the entire stent graft to be scanned and were rated as diagnostic. The mean effective radiation dose was 13.1 mSv. Endoleaks were detected in eight patients (type Ia, n = 1; type II, n = 6; type III, n = 1). Interobserver agreement (κ = 0.794) and intraobserver agreement (κ = 1.00) for detection of endoleaks were excellent. The mean time delay between peak enhancement of the aorta and the endoleaks was significantly less for type I/III endoleaks (2.0 s ± 0) compared with type II endoleaks (5.3 s ± 1.0; P < .001).
Conclusions: Low-dose dynamic volumetric CT angiography performed with the patient in Fowler position is feasible after EVAR. Dynamic information, including cine imaging, the timing of peak enhancement, and the Hounsfield units index, is useful in detecting and classifying endoleaks.
Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Dynamic CT angiography after abdominal aortic endovascular aneurysm repair: differences in contrast agent dynamics in the aorta and endoleaks--preliminary results.J Vasc Interv Radiol. 2012 Jun;23(6):744-50. doi: 10.1016/j.jvir.2012.02.008. Epub 2012 Apr 10. J Vasc Interv Radiol. 2012. PMID: 22494657
-
Preliminary experience with superparamagnetic iron oxide-enhanced dynamic magnetic resonance imaging and comparison with contrast-enhanced computed tomography in endoleak detection after endovascular aneurysm repair.J Vasc Surg. 2013 Jul;58(1):66-72. doi: 10.1016/j.jvs.2012.12.061. Epub 2013 Apr 2. J Vasc Surg. 2013. PMID: 23561434
-
Changes in Apposition of Endograft Limbs in the Iliac Arteries After Endovascular Aneurysm Repair: Determination With New Computed Tomography-Applied Software.J Endovasc Ther. 2019 Dec;26(6):843-852. doi: 10.1177/1526602819867430. Epub 2019 Aug 12. J Endovasc Ther. 2019. PMID: 31402731
-
Imaging of the endoleak after endovascular aneurysm repair procedure by using multidetector computer tomography angiography.J Cardiovasc Surg (Torino). 2009 Aug;50(4):515-26. J Cardiovasc Surg (Torino). 2009. PMID: 19734835 Review.
-
Intervention for type II endoleaks? "Primum non nocere": appraisal for the conservative management of low-pressure endoleaks after endovascular aneurysm repair.J Cardiovasc Surg (Torino). 2013 Aug;54(4):477-84. J Cardiovasc Surg (Torino). 2013. PMID: 24013536 Review.
Cited by
-
Quantitative analysis of dynamic computed tomography angiography for the detection of endoleaks after abdominal aorta aneurysm endovascular repair: A feasibility study.PLoS One. 2021 Jan 7;16(1):e0245134. doi: 10.1371/journal.pone.0245134. eCollection 2021. PLoS One. 2021. PMID: 33411747 Free PMC article. Clinical Trial.
-
Hemodynamic subtype classification of type II endoleaks using time-enhanced curves and its association with aneurysmal enlargement.JVS Vasc Sci. 2025 Apr 15;6:100288. doi: 10.1016/j.jvssci.2025.100288. eCollection 2025. JVS Vasc Sci. 2025. PMID: 40496270 Free PMC article.
-
Dynamic Computed Tomography Angiography as Imaging Method for Endoleak Classification after Endovascular Aneurysm Repair: A Case Series and Systematic Review of the Literature.Diagnostics (Basel). 2023 Feb 21;13(5):829. doi: 10.3390/diagnostics13050829. Diagnostics (Basel). 2023. PMID: 36899973 Free PMC article. Review.
-
Dynamic Volumetric Computed Tomography Angiography Is a Preferred Method for Unclassified Endoleaks by Conventional Computed Tomography Angiography After Endovascular Aortic Repair.J Am Heart Assoc. 2019 Apr 16;8(8):e012011. doi: 10.1161/JAHA.119.012011. J Am Heart Assoc. 2019. PMID: 30957675 Free PMC article.
-
The Role of Dynamic Computed Tomography Angiography in Endoleak Detection and Classification After Endovascular Aneurysm Repair: A Comprehensive Review.Diagnostics (Basel). 2025 Feb 4;15(3):370. doi: 10.3390/diagnostics15030370. Diagnostics (Basel). 2025. PMID: 39941300 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources