Comparative Study
. 2015 Jul;35(4):291-300.
doi: 10.1111/cpf.12163. Epub 2014 May 19.

Large variation in blood flow between left ventricular segments, as detected by adenosine stress dynamic CT perfusion

Affiliations
Comparative Study

Large variation in blood flow between left ventricular segments, as detected by adenosine stress dynamic CT perfusion

Jakob De Geer et al. Clin Physiol Funct Imaging. 2015 Jul.

Abstract

Background: Dynamic cardiac CT perfusion (CTP) is based on repeated imaging during the first-pass contrast agent inflow. It is a relatively new method that still needs validation.

Purpose: To evaluate the variation in adenosine stress dynamic CTP blood flow as compared to (99m) Tc SPECT. Secondarily, to compare manual and automatic segmentation.

Methods: Seventeen patients with manifest coronary artery disease were included. Nine were excluded from evaluation for various reasons. All patients were examined with dynamic stress CTP and stress/rest SPECT. CTP blood flow was compared with SPECT on a per segment basis. Results for manual and automated AHA segmentation were compared.

Results: CTP showed a positive correlation with SPECT, with correlation coefficients of 0·38 and 0·41 for manual and automatic segmentation, respectively (P<0·0001). There was no significant difference between the correlation coefficients of the manual and automated segmentation procedures (P = 0·75). The average per individual global CTP blood flow value for normal segments varied by a factor of 1·9 (manual and automatic segmentation). For the whole patient group, the CTP blood flow value in normal segments varied by a factor of 2·9/2·7 (manual/automatic segmentation). Within each patient, the average per segment blood flow in normal segments varied by a factor of 1·3-2·0/1·2-2·1 (manual/automatic segmentation).

Conclusion: A positive but rather weak correlation was found between CTP and (99m) Tc SPECT. Large variations in CTP blood flow suggest that a cut-off value for stress myocardial blood flow is inadequate to detect ischaemic segments. Dynamic CTP is hampered by a limited coverage.

Keywords: AHA segmentation; contrast agent; correlation; ischaemia; tetrofosmin.