Novel noninvasive approach for detecting arteriovenous fistula stenosis
- PMID: 24845295
- DOI: 10.1109/TBME.2014.2308906
Novel noninvasive approach for detecting arteriovenous fistula stenosis
Abstract
Hemodialysis is the most common treatment for patients with end-stage renal disease. For hemodialysis, consistently functional vascular access must be surgically created with an anastomosis of artery and vein, referred to as an arteriovenous fistula (AVF). However, AVF dysfunction may occur over time. Angiography and Doppler ultrasound are usually used to detect the flow or the diameter of the AVF. But they require well-trained operators and are expensive, and even angiography is invasive. In this study, a noninvasive approach based on stethoscope auscultation for monitoring AVF stenosis was proposed. Here, a wireless blood flow sound recorder was designed to record blood flow sounds wirelessly. In order to effectively extract the varying feature of blood flow sounds for AVF stenosis, the 2-D feature pattern built from S-transform was also proposed as the feature in the AVF stenosis detecting algorithm. Different from other frequency-related coefficients, the feature pattern can contain the information of blood flow sounds in time and frequency domains simultaneously. Preliminary findings showed that the proposed approach can provide high-quality estimation of AVF stenosis (positive predictive value = 87.84% and sensitivity = 89.24%).
Similar articles
-
Monitoring hemodialysis vascular access by digital phonoangiography.Ann Biomed Eng. 2002 Jul-Aug;30(7):982. doi: 10.1114/1.1497382. Ann Biomed Eng. 2002. PMID: 12398428
-
Evaluation of arteriovenous fistula for hemodialysis with a new generation digital stethoscope: a pilot study.Int Urol Nephrol. 2024 May;56(5):1763-1771. doi: 10.1007/s11255-023-03895-5. Epub 2023 Dec 13. Int Urol Nephrol. 2024. PMID: 38093038
-
Vascular dialysis access flow measurement: early intervention through early detection.J Ren Care. 2009 Dec;35(4):185-91. doi: 10.1111/j.1755-6686.2009.00114.x. J Ren Care. 2009. PMID: 19909411
-
The key role of color Doppler ultrasound in the work-up of hemodialysis vascular access.Semin Dial. 2015 Mar-Apr;28(2):211-5. doi: 10.1111/sdi.12312. Epub 2014 Sep 29. Semin Dial. 2015. PMID: 25264303 Review.
-
The native arteriovenous fistula in 2007. Surveillance and monitoring.J Nephrol. 2007 Nov-Dec;20(6):656-67. J Nephrol. 2007. PMID: 18046667 Review.
Cited by
-
Artificial neural networks analysis predicts long-term fistula function in hemodialysis patients following percutaneous transluminal angioplasty.EngMedicine. 2024 Jun;1(1):100010. doi: 10.1016/j.engmed.2024.100010. Epub 2024 May 15. EngMedicine. 2024. PMID: 38957294 Free PMC article.
-
SKIN-COUPLED PVDF MICROPHONES FOR NONINVASIVE VASCULAR BLOOD SOUND MONITORING.IEEE Signal Process Med Biol Symp. 2018 Dec;2018:10.1109/SPMB.2018.8615606. doi: 10.1109/SPMB.2018.8615606. Epub 2019 Jan 17. IEEE Signal Process Med Biol Symp. 2018. PMID: 31742227 Free PMC article.
-
The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis.Ann Biomed Eng. 2025 Jan;53(1):230-240. doi: 10.1007/s10439-024-03638-2. Epub 2024 Nov 1. Ann Biomed Eng. 2025. PMID: 39485642 Free PMC article. Clinical Trial.
-
Flow-induced high frequency vascular wall vibrations in an arteriovenous fistula: a specific stimulus for stenosis development?Phys Eng Sci Med. 2024 Mar;47(1):187-197. doi: 10.1007/s13246-023-01355-z. Epub 2023 Dec 29. Phys Eng Sci Med. 2024. PMID: 38157188 Free PMC article.
-
A Novel Classification Technique of Arteriovenous Fistula Stenosis Evaluation Using Bilateral PPG Analysis.Micromachines (Basel). 2016 Aug 23;7(9):147. doi: 10.3390/mi7090147. Micromachines (Basel). 2016. PMID: 30404320 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical