Cardiovascular MRI in Detection and Measurement of Aortic Atheroma in Stroke/TIA patients
- PMID: 24851233
- PMCID: PMC4025943
- DOI: 10.4172/2329-6895.1000139
Cardiovascular MRI in Detection and Measurement of Aortic Atheroma in Stroke/TIA patients
Abstract
Background: Aortic Atheroma (AoA) is an independent risk factor for new and recurrent stroke. AoA ulceration and mobility are associated with an increased risk for brain embolism. Transesophageal echocardiography (TEE) is the gold standard for detection and measurement of AoA in stroke/TIA patients. Cardiovascular MRI (cMRI) could be an alternative, non-invasive imaging modality for stroke/TIA patients. The objective of this study was to assess the accuracy and correlation of AoA detected and measured by cMRI versus TEE in patients with recent stroke/TIA.
Methods and results: Twenty-two stroke/TIA patients undergoing TEE as a part of their stroke workup consented to a protocol-mandated cMRI performed on a 1.5 T magnet. The protocol included an axial non-breathhold EKG-gated dual-echo spin echo MRI of the thoracic aorta (TR/TE1/TE2=900/29/69) and a contrast-enhanced breathhold 3D gradient-echo image of the thorax (flip/TR/TE=12/4.0/1.71). Maximum plaque thickness, ulceration (≥ 2 mm) and mobility of AoA were assessed in the proximal (ascending and proximal arch) and distal (distal arch and descending) segments of thoracic aorta by a cardiologist to interpret the TEE and a radiologist to interpret the cMRI. There was good correlation between cMRI and TEE in measurement of plaque thickness in the proximal segments (R=0.73, p<0.0001) and the distal segments (R=0.81, p<0.0001) of the aortic arch (AA). cMRI had a high degree of accuracy in detecting measurable AoA (≥ 1 mm) in the proximal segments (sensitivity 90%, specificity 100%), as well as the distal segments (sensitivity 67%, specificity 100%). cMRI also had a high degree of accuracy in detecting significant AoA (≥ 4 mm) in proximal segments (sensitivity 71%, specificity 93%), as well as distal segments (sensitivity 71%, specificity 100%).
Conclusion: The study showed a high degree of accuracy and correlation of AoA detected and measured by cMRI as compared to TEE in patients with recent stroke/TIA. This technique has limitations in detection of AoA ulceration, and protocols assessing AoA mobility need to be developed.
Keywords: Aortic atheroma; Cardiovascular MRI; Transesophogeal echocardiogram.
Figures
References
-
- Go AS, Mozaffarian D, Roger VL, Benjamin EJ, Berry JD, et al. Executive summary: heart disease and stroke statistics--2013 update: a report from the American Heart Association. Circulation. 2013;127:143–152. - PubMed
-
- Morris JG, Duffis EJ, Fisher M. Cardiac workup of ischemic stroke: can we improve our diagnostic yield? Stroke. 2009;40:2893–2898. - PubMed
-
- Sacco RL, Ellenberg JH, Mohr JP, Tatemichi TK, Hier DB, et al. Infarcts of undetermined cause: the NINCDS Stroke Data Bank. Ann Neurol. 1989;25:382–390. - PubMed
-
- Petty GW, Brown RD, Jr, Whisnant JP, Sicks JD, O’Fallon WM, et al. Ischemic stroke subtypes: a population-based study of incidence and risk factors. Stroke. 1999;30:2513–2516. - PubMed
-
- Lee BI, Nam HS, Heo JH, Kim DI Yonsei Stroke Team. Yonsei Stroke Registry. Analysis of 1,000 patients with acute cerebral infarctions. Cerebrovasc Dis. 2001;12:145–151. - PubMed
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources