Recovery of hypoglycemia awareness in long-standing type 1 diabetes: a multicenter 2 × 2 factorial randomized controlled trial comparing insulin pump with multiple daily injections and continuous with conventional glucose self-monitoring (HypoCOMPaSS)
- PMID: 24854041
- DOI: 10.2337/dc14-0030
Recovery of hypoglycemia awareness in long-standing type 1 diabetes: a multicenter 2 × 2 factorial randomized controlled trial comparing insulin pump with multiple daily injections and continuous with conventional glucose self-monitoring (HypoCOMPaSS)
Abstract
Objective: To determine whether impaired awareness of hypoglycemia (IAH) can be improved and severe hypoglycemia (SH) prevented in type 1 diabetes, we compared an insulin pump (continuous subcutaneous insulin infusion [CSII]) with multiple daily injections (MDIs) and adjuvant real-time continuous glucose monitoring (RT) with conventional self-monitoring of blood glucose (SMBG).
Research design and methods: A 24-week 2 × 2 factorial randomized controlled trial in adults with type 1 diabetes and IAH was conducted. All received comparable education, support, and congruent therapeutic targets aimed at rigorous avoidance of biochemical hypoglycemia without relaxing overall control. Primary end point was between-intervention difference in 24-week hypoglycemia awareness (Gold score).
Results: A total of 96 participants (mean diabetes duration 29 years) were randomized. Overall, biochemical hypoglycemia (≤3.0 mmol/L) decreased (53 ± 63 to 24 ± 56 min/24 h; P = 0.004 [t test]) without deterioration in HbA1c. Hypoglycemia awareness improved (5.1 ± 1.1 to 4.1 ± 1.6; P = 0.0001 [t test]) with decreased SH (8.9 ± 13.4 to 0.8 ± 1.8 episodes/patient-year; P = 0.0001 [t test]). At 24 weeks, there was no significant difference in awareness comparing CSII with MDI (4.1 ± 1.6 vs. 4.2 ± 1.7; difference 0.1; 95% CI -0.6 to 0.8) and RT with SMBG (4.3 ± 1.6 vs. 4.0 ± 1.7; difference -0.3; 95% CI -1.0 to 0.4). Between-group analyses demonstrated comparable reductions in SH, fear of hypoglycemia, and insulin doses with equivalent HbA1c. Treatment satisfaction was higher with CSII than MDI (32 ± 3 vs. 29 ± 6; P = 0.0003 [t test]), but comparable with SMBG and RT (30 ± 5 vs. 30 ± 5; P = 0.79 [t test]).
Conclusions: Hypoglycemia awareness can be improved and recurrent SH prevented in long-standing type 1 diabetes without relaxing HbA1c. Similar biomedical outcomes can be attained with conventional MDI and SMBG regimens compared with CSII/RT, although satisfaction was higher with CSII.
© 2014 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.
Comment in
-
Comment on Little et al. Recovery of hypoglycemia awareness in long-standing type 1 diabetes: a multicenter 2 × 2 factorial randomized controlled trial comparing insulin pump with multiple daily injections and continuous with conventional glucose self-monitoring (HypoCOMPaSS). Diabetes Care 2014;37:2114-2122.Diabetes Care. 2014 Dec;37(12):e270-1. doi: 10.2337/dc14-1736. Diabetes Care. 2014. PMID: 25414404 No abstract available.
-
Response to comment on Little et al. Recovery of hypoglycemia awareness in long-standing type 1 diabetes: a multicenter 2 × 2 factorial randomized controlled trial comparing insulin pump with multiple daily injections and continuous with conventional glucose self-monitoring (HypoCOMPaSS). Diabetes Care 2014;37:2114-2122.Diabetes Care. 2014 Dec;37(12):e272-3. doi: 10.2337/dc14-1947. Diabetes Care. 2014. PMID: 25414405 No abstract available.
Similar articles
-
Restoration of self-awareness of hypoglycemia in adults with long-standing type 1 diabetes: hyperinsulinemic-hypoglycemic clamp substudy results from the HypoCOMPaSS trial.Diabetes Care. 2013 Dec;36(12):4063-70. doi: 10.2337/dc13-1004. Epub 2013 Oct 15. Diabetes Care. 2013. PMID: 24130355 Free PMC article. Clinical Trial.
-
Sustained Reduction in Severe Hypoglycemia in Adults With Type 1 Diabetes Complicated by Impaired Awareness of Hypoglycemia: Two-Year Follow-up in the HypoCOMPaSS Randomized Clinical Trial.Diabetes Care. 2018 Aug;41(8):1600-1607. doi: 10.2337/dc17-2682. Epub 2018 Apr 16. Diabetes Care. 2018. PMID: 29661916 Clinical Trial.
-
Satisfaction with the Use of Different Technologies for Insulin Delivery and Glucose Monitoring Among Adults with Long-Standing Type 1 Diabetes and Problematic Hypoglycemia: 2-Year Follow-Up in the HypoCOMPaSS Randomized Clinical Trial.Diabetes Technol Ther. 2019 Nov;21(11):619-626. doi: 10.1089/dia.2019.0152. Epub 2019 Oct 9. Diabetes Technol Ther. 2019. PMID: 31335201 Clinical Trial.
-
Optimizing type 1 diabetes after multiple daily injections and capillary blood monitoring: Pump or sensor first? A meta-analysis using pooled differences in outcome measures.Diabetes Obes Metab. 2021 Nov;23(11):2521-2528. doi: 10.1111/dom.14498. Epub 2021 Aug 12. Diabetes Obes Metab. 2021. PMID: 34286892
-
Severe hypoglycaemia and glycaemic control in Type 1 diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion.Diabet Med. 2008 Jul;25(7):765-74. doi: 10.1111/j.1464-5491.2008.02486.x. Diabet Med. 2008. PMID: 18644063 Review.
Cited by
-
Continuous Glucose Monitoring with Multiple Daily Insulin Treatment: Outcome Studies.Diabetes Technol Ther. 2017 Jun;19(S3):S3-S12. doi: 10.1089/dia.2017.0090. Diabetes Technol Ther. 2017. PMID: 28585875 Free PMC article. Review.
-
2023 Clinical Practice Guidelines for Diabetes Management in Korea: Full Version Recommendation of the Korean Diabetes Association.Diabetes Metab J. 2024 Jul;48(4):546-708. doi: 10.4093/dmj.2024.0249. Epub 2024 Jul 26. Diabetes Metab J. 2024. PMID: 39091005 Free PMC article. No abstract available.
-
A parallel randomised controlled trial of the Hypoglycaemia Awareness Restoration Programme for adults with type 1 diabetes and problematic hypoglycaemia despite optimised self-care (HARPdoc).Nat Commun. 2022 Apr 28;13(1):2229. doi: 10.1038/s41467-022-29488-x. Nat Commun. 2022. PMID: 35484106 Free PMC article. Clinical Trial.
-
A Randomized Clinical Trial of the Effect of Continuous Glucose Monitoring on Nocturnal Hypoglycemia, Daytime Hypoglycemia, Glycemic Variability, and Hypoglycemia Confidence in Persons with Type 1 Diabetes Treated with Multiple Daily Insulin Injections (GOLD-3).Diabetes Technol Ther. 2018 Apr;20(4):274-284. doi: 10.1089/dia.2017.0363. Epub 2018 Apr 2. Diabetes Technol Ther. 2018. PMID: 29608107 Free PMC article. Clinical Trial.
-
Glycemic Status Assessment by the Latest Glucose Monitoring Technologies.Int J Mol Sci. 2020 Nov 3;21(21):8243. doi: 10.3390/ijms21218243. Int J Mol Sci. 2020. PMID: 33153229 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical