Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 May;19(5):482-9.
doi: 10.1111/1756-185X.12380. Epub 2014 May 26.

High serum level of haptoglobin is associated with the response of 12 weeks methotrexate therapy in recent-onset rheumatoid arthritis patients

Affiliations

High serum level of haptoglobin is associated with the response of 12 weeks methotrexate therapy in recent-onset rheumatoid arthritis patients

Wenfeng Tan et al. Int J Rheum Dis. 2016 May.

Abstract

Background: We previously found, using microarray, haptoglobin (HP) expression signal was 5.1-fold increased in peripheral blood mononuclear cells (PBMCs) from methotrexate (MTX)-resistant rheumatoid arthritis (RA) patients.

Objectives: To investigate whether serum levels of HP are associated with the response of 12 weeks MTX therapy in recent-onset RA patients.

Methods: Sixty-nine active RA patients with recent onset (< 24 months) were treated with MTX. Clinical variables, levels of HP messenger RNA (mRNA) in PBMCs and HP serum levels were tested at week 0 and week 12.

Results: After 12 weeks of MTX treatment, 34.7% of RA patients were categorized as responders according to European League Against Rheumatism (EULAR) response criteria (Week 12 Disease Activity Score of 28 joints [DAS-28] ≤ 3.2 and decrease > 1.2) and all others (65.2%) were defined as non-responders. The baseline HP mRNA in PBMCs from non-responders is significantly higher than those in responders (P < 0.05). Similar to mRNA expression, non-responders showed significantly elevated serum HP levels at baseline (369.9 ± 159.8 mg/dL) compared to those in responders (255.3 ± 143.9 mg/dL) (P = 0.01). Serum HP levels were decreased significantly from 255.3 ± 143.9 mg/dL at baseline to 186.4 ± 108.5 mg/dL at week 12 (P = 0.04) in responders, but remained at high levels in non-responders.

Conclusions: High serum levels of HP at baseline are associated with inadequate response of 12 weeks MTX treatment in recent-onset RA patients. Further replication studies in larger samples are needed to validate HP as a potential predictive biomarker for response to MTX therapy in RA.

Keywords: haptoglobin; methotrexate; rheumatoid arthritis.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms