What type of valve is most appropriate for osteogenesis imperfecta patients?
- PMID: 24876219
- DOI: 10.1093/icvts/ivu152
What type of valve is most appropriate for osteogenesis imperfecta patients?
Abstract
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was in osteogenesis imperfecta (OI) patients with valve disease undergoing valve replacement which type of valve (bioprosthetic or mechanical) is most appropriate in terms of safety, complications and survival. Altogether more than 77 papers were found as a result of the reported search, of which 43 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Previous review articles have presented case reports up to 2009. As all published data are based on case reports, we conducted a more detailed analysis that included the aforementioned series, reports that were missed prior to 2009 and all published data from 2009 to October 2013. Our analysis identified 43 OI patients. Mechanical valves were used in the majority of cases (31 patients), bioprosthetic valves in 10 patients and homografts in 2 patients. We conclude that based on the best available evidence, it appears that bioprosthetic valves have had better outcomes (mortality rate 10%) and a lower valve-related complication rate (0%) compared with mechanical valves (mortality rate 16.1%, complication rate 16.1%), even though differences were not statistically significant. Although the existing evidence is solely based on case reports of a relatively small number, we would suggest the use of bioprosthetic valves in OI patients with valve disease, as they appear to be safer according to our analysis. Moreover, considering the surgical difficulties related to the friability and weakness of the tissues in terms of suture lines and implantation of the valve as well as the high risk of perioperative bleeding which can be related to tissue friability, capillary fragility and platelet dysfunction followed by the risk of major traumatic fractures and a possible risk of aortic dissection in the future, the bioprosthetic valves seem to be safer taking into account the avoidance of lifelong anticoagulation and its secondary bleeding complications.
Keywords: Bioprosthetic; Cardiac surgery; Mechanical; Osteogenesis imperfecta; Valve replacement.
© The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Similar articles
-
What is the best approach in a patient with a failed aortic bioprosthetic valve: transcatheter aortic valve replacement or redo aortic valve replacement?Interact Cardiovasc Thorac Surg. 2015 Jun;20(6):837-43. doi: 10.1093/icvts/ivv037. Epub 2015 Mar 8. Interact Cardiovasc Thorac Surg. 2015. PMID: 25754372 Review.
-
What type of valve replacement should be used in patients with endocarditis?Interact Cardiovasc Thorac Surg. 2010 Dec;11(6):784-8. doi: 10.1510/icvts.2010.234450. Epub 2010 Aug 16. Interact Cardiovasc Thorac Surg. 2010. PMID: 20713537 Review.
-
Do statins slow the process of calcification of aortic tissue valves?Interact Cardiovasc Thorac Surg. 2010 Sep;11(3):297-301. doi: 10.1510/icvts.2009.230920. Epub 2010 Jun 22. Interact Cardiovasc Thorac Surg. 2010. PMID: 20570976 Review.
-
Is there a role for mechanical valve prostheses in pulmonary valve replacement late after tetralogy of Fallot repair?Interact Cardiovasc Thorac Surg. 2014 May;18(5):661-6. doi: 10.1093/icvts/ivt541. Epub 2014 Jan 30. Interact Cardiovasc Thorac Surg. 2014. PMID: 24480820 Review.
-
National trends in utilization and in-hospital outcomes of mechanical versus bioprosthetic aortic valve replacements.J Thorac Cardiovasc Surg. 2015 May;149(5):1262-9.e3. doi: 10.1016/j.jtcvs.2015.01.052. Epub 2015 Feb 11. J Thorac Cardiovasc Surg. 2015. PMID: 25791947
Cited by
-
Aortic valve reconstruction with autologous pericardium in a patient with osteogenesis imperfecta.J Surg Case Rep. 2018 Oct 5;2018(10):rjy251. doi: 10.1093/jscr/rjy251. eCollection 2018 Oct. J Surg Case Rep. 2018. PMID: 30310641 Free PMC article.
-
Case Report: A usual procedure in an unusual situation: a patient with a rare Ehlers Danlos/osteogenesis imperfecta overlap undergoing aortic valve replacement.Front Cardiovasc Med. 2025 Feb 24;12:1480363. doi: 10.3389/fcvm.2025.1480363. eCollection 2025. Front Cardiovasc Med. 2025. PMID: 40066355 Free PMC article.
-
[Late discovery of type III osteogenesis imperfecta: about a case].Pan Afr Med J. 2015 Jan 6;20:14. doi: 10.11604/pamj.2015.20.14.5382. eCollection 2015. Pan Afr Med J. 2015. PMID: 25995811 Free PMC article. French.
Publication types