Can glucose be monitored accurately at the site of subcutaneous insulin delivery?
- PMID: 24876621
- PMCID: PMC4455428
- DOI: 10.1177/1932296814522805
Can glucose be monitored accurately at the site of subcutaneous insulin delivery?
Abstract
Because insulin promotes glucose uptake into adipocytes, it has been assumed that during measurement of glucose at the site of insulin delivery, the local glucose level would be much lower than systemic glucose. However, recent investigations challenge this notion. What explanations could account for a reduced local effect of insulin in the subcutaneous space? One explanation is that, in humans, the effect of insulin on adipocytes appears to be small. Another is that insulin monomers and dimers (from hexamer disassociation) might be absorbed into the circulation before they can increase glucose uptake locally. In addition, negative cooperativity of insulin action (a lower than expected effect of very high insulin concentrations)may play a contributing role. Other factors to be considered include dilution of interstitial fluid by the insulin vehicle and the possibility that some of the local decline in glucose might be due to the systemic effect of insulin. With regard to future research, redundant sensing units might be able to quantify the effects of proximity, leading to a compensatory algorithm. In summary, when measured at the site of insulin delivery, the decline in subcutaneous glucose level appears to be minimal, though the literature base is not large. Findings thus far support (1) the development of integrated devices that monitor glucose and deliver insulin and (2) the use of such devices to investigate the relationship between subcutaneous delivery of insulin and its local effects on glucose. A reduction in the number of percutaneous devices needed to manage diabetes would be welcome.
Keywords: adipocytes; continuous glucose monitoring; glucose uptake; insulin delivery; type 1 diabetes.
© 2014 Diabetes Technology Society.
Conflict of interest statement
Similar articles
-
Treatment satisfaction and quality of life for an integrated continuous glucose monitoring/insulin pump system compared to self-monitoring plus an insulin pump.J Diabetes Sci Technol. 2009 Nov 1;3(6):1402-10. doi: 10.1177/193229680900300621. J Diabetes Sci Technol. 2009. PMID: 20144395 Free PMC article.
-
Deus ex machina: the use of technology in type 1 diabetes.Prim Care Diabetes. 2011 Oct;5(3):159-65. doi: 10.1016/j.pcd.2010.11.001. Epub 2011 Jul 2. Prim Care Diabetes. 2011. PMID: 21727052 Review.
-
Periodic extraction of interstitial fluid from the site of subcutaneous insulin infusion for the measurement of glucose: a novel single-port technique for the treatment of type 1 diabetes patients.Diabetes Technol Ther. 2013 Jan;15(1):50-9. doi: 10.1089/dia.2012.0173. Epub 2012 Nov 5. Diabetes Technol Ther. 2013. PMID: 23126579 Free PMC article.
-
Run-to-run tuning of model predictive control for type 1 diabetes subjects: in silico trial.J Diabetes Sci Technol. 2009 Sep 1;3(5):1091-8. doi: 10.1177/193229680900300512. J Diabetes Sci Technol. 2009. PMID: 20144422 Free PMC article.
-
A Technological Revolution: The Integration of New Treatments to Manage Type 1 Diabetes.Pediatr Ann. 2019 Aug 1;48(8):e311-e318. doi: 10.3928/19382359-20190725-03. Pediatr Ann. 2019. PMID: 31426099 Review.
Cited by
-
An Amperometric Glucose Sensor Integrated into an Insulin Delivery Cannula: In Vitro and In Vivo Evaluation.Diabetes Technol Ther. 2017 Apr;19(4):226-236. doi: 10.1089/dia.2016.0407. Epub 2017 Feb 21. Diabetes Technol Ther. 2017. PMID: 28221814 Free PMC article.
-
Combining Glucose Monitoring and Insulin Infusion in an Integrated Device: A Narrative Review of Challenges and Proposed Solutions.J Diabetes Sci Technol. 2025 Mar;19(2):441-451. doi: 10.1177/19322968231203237. Epub 2023 Oct 5. J Diabetes Sci Technol. 2025. PMID: 37798963 Free PMC article. Review.
-
Fabrication of a Flexible Amperometric Glucose Sensor Using Additive Processes.ECS J Solid State Sci Technol. 2015;4(4):P3069-P3074. doi: 10.1149/2.0101504jss. Epub 2015 Feb 18. ECS J Solid State Sci Technol. 2015. PMID: 26634186 Free PMC article.
References
-
- Phillip M, Battelino T, Atlas E, et al. Nocturnal glucose control with an artificial pancreas at a diabetes camp. N Engl J Med. 2013;368:824-833. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical