Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Apr;7(2):159-164.
doi: 10.4103/1305-7456.110157.

Reliability analysis of two methods for measuring active enamel demineralization: An in vitro study

Affiliations

Reliability analysis of two methods for measuring active enamel demineralization: An in vitro study

Camila Nassur et al. Eur J Dent. 2013 Apr.

Abstract

Objective: The aim was to evaluate the intra- and inter-examiner reliability of two methods, namely, digital caliper [DC] and computerized image analysis software (Image Tool [IT] version 4.1) for measuring the area of an active enamel demineralization lesion. The effect on that measurement of a window that delimits the lesion was also assessed.

Materials and methods: Thirty-eight circular artificial enamel demineralization lesions (r = 2 mm) were produced on bovine teeth in vitro, which were then measured three times by three examiners, with and without the presence of a window delimiting the area to be measured. The data were analyzed by the intraclass correlation coefficient (ICC) with 95% confidence interval (CI) and by the Altman and Bland analysis.

Results: The intra-examiner correlation using the IT method showed excellent reproducibility (mean ICC values 0.922-0.970 with the delimiting window and 0.915-0.990 without the window). However, the intra-examiner correlation using the DC method showed comparatively less reproducibility in the measurements (mean ICC values 0.458-0.648 with the delimiting window and 0.378-0.665 without the window). The inter-examiner correlations showed very good reproducibility of the measurements regardless of the presence or absence of the window for both the DC method (0.811-0.846) and IT method (0.953-0.994). However, the latter method showed less variability within the measurements.

Conclusion: However, statistically no significant difference was found between both methodologies. Nevertheless, computerized image analysis with the Image Tool software demonstrated higher intra- and inter-examiner reliability than the digital caliper method, in estimating the area of the enamel demineralization lesion, regardless of the delimiting window.

Keywords: Computerized image analysis; dental caries; image processing; observer variation; reproducibility of results; tooth demineralization.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: None declared

Figures

Figure 1
Figure 1
Photographic apparatus used for standardization of distance and angulation
Figure 2
Figure 2
Dental fragments with (a) and without (b) window. Note the millimeter rule used as a metric parameter for further measurements
Figure 3
Figure 3
Comparison between digital caliper (a) and image tool software (b), with presence (1) and absence (2) of a window established according to Altman and Bland analysis

Similar articles

References

    1. Featherstone JD. The continuum of dental caries-evidence for a dynamic disease process. J Dent Res. 2004;83(special No C):C39–42. - PubMed
    1. Featherstone JD. Prevention and reversal of dental caries: role of low level fluoride. Community Dent Oral Epidemiol. 1999;27:31–40. - PubMed
    1. Arends J, Christoffersen J. The nature of early caries lesions in enamel. J Dent Res. 1986;65:2–11. - PubMed
    1. Featherstone JD. Caries detection and prevention with laser energy. Dent Clin North Am. 2000;44:955–69. - PubMed
    1. Pereira AC, Verdonschot EH, Huysmans MC. Caries detection methods: Can they aid decision making for invasive sealant treatment? Caries Res. 2001;35:83–9. - PubMed