Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Feb;37(1):58-65.
doi: 10.1097/FTD.0000000000000102.

Development of a pharmacokinetic model of mitotane: toward personalized dosing in adrenocortical carcinoma

Affiliations

Development of a pharmacokinetic model of mitotane: toward personalized dosing in adrenocortical carcinoma

Thomas M A Kerkhofs et al. Ther Drug Monit. 2015 Feb.

Abstract

Background: Mitotane is the drug of choice in medical treatment of adrenocortical carcinoma. The antineoplastic effect seems to be correlated with a minimum plasma level of 14 mg/L, but plasma concentration build-up is in general slow due to the long elimination half-life. Consequently, the therapeutic effect sets in after weeks or even months. The objective of this study was to develop a pharmacokinetic model that enables clinicians to adjust dosing based on a target drug exposure, which facilitates personalized therapy.

Methods: Data on dosing and plasma level measurements performed throughout mitotane therapy were retrospectively collected in a population of 29 patients from 2 hospitals. A population pharmacokinetic model was constructed based on data from 20 patients using iterative 2-stage Bayesian fitting (MWPharm). The model was validated in an independent sample of 9 patients.

Results: The concentration-time data were best described by a 3-compartment model. The model estimated mitotane clearance at 0.94 ± 0.37 L/h and a volume of distribution in the steady state at 161 ± 68 L/kg of lean body mass. The mean prediction error was 14% ± 13%.

Conclusions: A pharmacokinetic model was developed, which characterized mitotane by slow clearance and large volume of distribution. The model seems to be able to predict mitotane levels in individual patients with an error margin of 14%. The model enables one to adapt dosing based on individual plasma level measurements in prospective setting, which improves the accuracy of the prediction. We expect that individualization of mitotane dosing leads to anticipated and more rapid attainment of the therapeutic levels and potentially to improved clinical management of mitotane treatment.

PubMed Disclaimer

MeSH terms

LinkOut - more resources