Surrogate measures of insulin sensitivity vs the hyperinsulinaemic-euglycaemic clamp: a meta-analysis
- PMID: 24891021
- DOI: 10.1007/s00125-014-3285-x
Surrogate measures of insulin sensitivity vs the hyperinsulinaemic-euglycaemic clamp: a meta-analysis
Abstract
Aims/hypothesis: We aimed to identify which surrogate index of insulin sensitivity has the strongest correlation with the reference measurement, the hyperinsulinaemic-euglycaemic clamp (HEC), to determine which surrogate measure should be recommended for use in large-scale studies.
Methods: A literature search (1979-2012) was conducted to retrieve all articles reporting bivariate correlations between the HEC and surrogate measures of insulin sensitivity (in fasting samples or during the OGTT). We performed a random effects meta-analysis for each surrogate measure to integrate the correlation coefficients of the different studies.
Results: The OGTT-based surrogate measures with the strongest pooled correlations (r) to the HEC were the Stumvoll metabolic clearance rate (Stumvoll MCR; r = 0.70 [95% CI 0.61, 0.77], n = 5), oral glucose insulin sensitivity (OGIS; r = 0.70 [0.57, 0.80], n = 6), the Matsuda index (r = 0.67 [0.61, 0.73], n = 19), the Stumvoll insulin sensitivity index (Stumvoll ISI; r = 0.67 [0.60, 0.72], n = 8) and the Gutt index (r = 0.65 [0.60, 0.69], n = 6). The fasting surrogate indices that correlated most strongly with the HEC and had narrow 95% CIs were the revised QUICKI (r = 0.68 [0.58, 0.77], n = 7), the QUICKI (r = 0.61 [0.55, 0.65], n = 35), the log HOMA-IR (r = -0.60 [-0.66, -0.53], n = 22) and the computer generated HOMA of insulin sensitivity (HOMA-%S; r = 0.57 [0.46, 0.67], n = 5).
Conclusions/interpretation: The revised QUICKI fasting surrogate measure appears to be as good as the OGTT-based Stumvoll MCR, OGIS, Matsuda, Stumvoll ISI and Gutt indices for estimating insulin sensitivity. It can therefore be recommended as the most appropriate index for use in large-scale clinical studies.
Comment in
-
Evidence-based estimation of insulin resistance.Diabetologia. 2014 Sep;57(9):1743-5. doi: 10.1007/s00125-014-3322-9. Epub 2014 Jul 17. Diabetologia. 2014. PMID: 25031068
-
Surrogate measures of insulin sensitivity vs the hyperinsulinaemic-euglycaemic clamp: a meta-analysis. Are there not some surrogate indexes lost in this story?Diabetologia. 2015 Feb;58(2):414-5. doi: 10.1007/s00125-014-3424-4. Epub 2014 Oct 24. Diabetologia. 2015. PMID: 25341461 No abstract available.
-
Surrogate measures of insulin sensitivity vs the hyperinsulinaemic-euglycaemic clamp: a meta-analysis. Are there not some surrogate indexes lost in this story? Reply to Bastard JP, Rabasa-Lhoret R, Laville M and Disse E [letter].Diabetologia. 2015 Feb;58(2):416-7. doi: 10.1007/s00125-014-3449-8. Epub 2014 Nov 22. Diabetologia. 2015. PMID: 25416407 No abstract available.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources