Review
. 2014 Jun;59(6):974-89; discussion 989-90.
doi: 10.4187/respcare.03246.

Management of the artificial airway

Affiliations
Review

Management of the artificial airway

Richard D Branson et al. Respir Care. 2014 Jun.

Abstract

Management of the artificial airway includes securing the tube to prevent dislodgement or migration as well as removal of secretions. Preventive measures include adequate humidification and appropriate airway suctioning. Monitoring airway patency and removing obstruction are potentially life-saving components of airway management. Cuff pressure management is important for preventing aspiration and mucosal damage as well as assuring adequate ventilation. A number of new monitoring techniques have been introduced, and automated cuff pressure control is becoming more common. The respiratory therapist should be adept with all these devices and understand the appropriate application and management.

Keywords: Artificial airway; humidification; mechanical ventilation.