The purpose of this study is to present a national survey that was performed in Greece for the establishment of national Dose Reference Levels (DRLs) for seven common adult Computed Tomography (CT) examinations. Volumetric computed tomography dose index and dose-length product values were collected from the post-data page of 65 'modern' systems that incorporate tube current modulation. Moreover, phantom dose measurements on 26 'older' systems were performed. Finally, the effective dose to the patient from a typical acquisition during these examinations was estimated. The suggested national DRLs are generally comparable with respective published values from similar European studies, with the exception of sinuses CT, which presents significantly higher values. This fact, along with the large variation of the systems' dose values that were observed even for scanners of the same type, indicates a need for further patient protection optimisation without compromising the clinical outcome.
© The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Similar articles
-
Image quality and patient dose in computed tomography examinations in Greece.Radiat Prot Dosimetry. 2011 Sep;147(1-2):129-32. doi: 10.1093/rpd/ncr282. Epub 2011 Jul 9. Radiat Prot Dosimetry. 2011. PMID: 21743078
-
Effective dose variation in pediatric computed tomography: dose reference levels in Greece.Health Phys. 2009 Dec;97(6):595-603. doi: 10.1097/01.HP.0000363840.78169.1b. Health Phys. 2009. PMID: 19901594
-
Updating national diagnostic reference levels for computed tomography in Greece: Challenges on patient protection optimisation.Eur J Radiol. 2024 Jun;175:111429. doi: 10.1016/j.ejrad.2024.111429. Epub 2024 Mar 16. Eur J Radiol. 2024. PMID: 38508091
-
Dosimetric comparison between different quantities for limiting exposure in the RF band: rationale and implications for guidelines.Health Phys. 2007 Jun;92(6):547-53. doi: 10.1097/01.HP.0000236788.33488.65. Health Phys. 2007. PMID: 17495655 Review.
-
Rapporteur Report: ICNIRP international workshop on EMF dosimetry and biophysical aspects relevant to setting exposure guidelines.Health Phys. 2007 Jun;92(6):658-67. doi: 10.1097/01.HP.0000257847.16768.13. Health Phys. 2007. PMID: 17495669
Cited by
-
Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?Eur Radiol. 2019 Jun;29(6):2878-2889. doi: 10.1007/s00330-018-5850-z. Epub 2018 Nov 30. Eur Radiol. 2019. PMID: 30506223
-
Computed Tomography Dose Level in Selected Five Principal Hospitals in Ethiopia.Ethiop J Health Sci. 2023 Nov;33(6):1005-1014. doi: 10.4314/ejhs.v33i6.11. Ethiop J Health Sci. 2023. PMID: 38784484 Free PMC article.
-
Evaluation of Impact of Factors Affecting CT Radiation Dose for Optimizing Patient Dose Levels.Diagnostics (Basel). 2020 Oct 5;10(10):787. doi: 10.3390/diagnostics10100787. Diagnostics (Basel). 2020. PMID: 33028021 Free PMC article.
-
Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT.AJR Am J Roentgenol. 2020 Apr;214(4):738-746. doi: 10.2214/AJR.19.21197. Epub 2019 Aug 15. AJR Am J Roentgenol. 2020. PMID: 31414882 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources